2010
DOI: 10.1109/tpel.2010.2077312
|View full text |Cite
|
Sign up to set email alerts
|

Full Feedforward of Grid Voltage for Grid-Connected Inverter With LCL Filter to Suppress Current Distortion Due to Grid Voltage Harmonics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
139
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 315 publications
(140 citation statements)
references
References 23 publications
1
139
0
Order By: Relevance
“…AD strategies based on feedback compensation are in essence the same while their differences mainly lie in the choice of states for feedback. Typical applications of proportional i C1 feedback can be found in [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34]. For 1 storder derivative feedback of u C1 , a high-pass filter (HPF) with a similar response is an alternative solution [35].…”
Section: Ad Subject To Different Options Of Single Statementioning
confidence: 99%
See 2 more Smart Citations
“…AD strategies based on feedback compensation are in essence the same while their differences mainly lie in the choice of states for feedback. Typical applications of proportional i C1 feedback can be found in [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34]. For 1 storder derivative feedback of u C1 , a high-pass filter (HPF) with a similar response is an alternative solution [35].…”
Section: Ad Subject To Different Options Of Single Statementioning
confidence: 99%
“…Consequently, grid voltage harmonics in the case of u C1 , i C1 , i L1 and u L1 feedback will have extra impact on the grid current quality. For this reason, the full feedforward method uses a 1 st -order derivative feedforward of u g to improve the grid current quality in [19] and [47]. The above investigations are also synthesized in Table 4.…”
Section: Current Distortion Caused By Grid Voltage Harmonicsmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to mitigate the effect of the grid voltage on the quality of LCL-filter currents, a feed-forward loop of the grid voltage and the multiple resonant regulators at the harmonic frequencies of grid voltages are applied in the current loop. According to (15), setting 1-GN(s)G1(s) to zero and adopting approximate full compensation approach, the feed-forward function is derived as (19) Considering that derivative functions are difficult to be implemented and mainly for middle-and higher-frequency harmonics, and the noise amplification problems would reduce the stability margin, hence (19) is approximated by a first order low pass filter, and the higher order differential terms are neglected to avoid high frequency instabilities [29], [33]. As shown in Fig.…”
Section: And W(s)=g1(s)g2(s)mentioning
confidence: 99%
“…G ff is the grid voltage feed-forward function, and in most cases, it can be simplified to 1 Fig. 1 Topology of a three-phase LCL filtered grid-connected inverter Stability of LCL-filtered grid-connected inverters with capacitor current feedback active… 585 (G ff & 1) when the grid voltage is mainly distorted by low-frequency harmonics [19].…”
Section: Introductionmentioning
confidence: 99%