Full 3D-3C velocity measurement inside a liquid immersion droplet

Abstract: We describe a tomographic PIV system for the measurement of the internal flow in a droplet over a stagnant and a moving surface. The flow condition is representative of the flow in an immersion droplet applied in a liquid immersion lithography machine. We quantify the accuracy and reliability of the measurements and compare the shape of the reconstructed measurement volume to shape measurements by means of shadowgraphy. First results indicate the internal flow pattern near the receding contact line, showing a … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
27
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 34 publications
(28 citation statements)
references
References 22 publications
(20 reference statements)
1
27
0
Order By: Relevance
“…4. Viewing angles of 20°were reported by Kim et al (2011), who used a self-made microscope and applied four cameras to investigate the flow inside a droplet on a moving surface tomographically. The measurement volume was 2.5 9 2.1 9 0.4 mm 3 .…”
Section: Tomographic Imagingmentioning
confidence: 99%
“…4. Viewing angles of 20°were reported by Kim et al (2011), who used a self-made microscope and applied four cameras to investigate the flow inside a droplet on a moving surface tomographically. The measurement volume was 2.5 9 2.1 9 0.4 mm 3 .…”
Section: Tomographic Imagingmentioning
confidence: 99%
“…Furthermore, this method is able to reconstruct the liquid-air interface by an average-reconstructed intensity distribution. (15) For multi-camera measurement technique, an inverted (i.e., upsidedown) custom-made microscope (Carl Zeiss Neolumar S1.5×) is equipped with optical filters set and with four dual-frame CCD cameras (LaVision Imager intense, 1376 × 1040 pixels, 12-bit dynamic range) is used for imaging, as shown in figure 1.…”
Section: Tomographic Pivmentioning
confidence: 99%
“…It is still challenging work to measure a flow field directly through the liquid-gas interface. In other ways, to minimize the optical distortion through the media, an inverted measurement system is commonly used (14,15) . Pradhan and Panigrahi (14) performed the flow field measurement inside the evaporating droplet by using scanning confocal microscope.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations