FTIR Identification of the ν4u) and ν6u) Modes of Linear GeC3Ge Trapped in Solid Ar

Abstract: GeC 3Ge was previously (1) produced by the dual laser ablation of germanium and carbon rods, and the nu 3(sigma u) carbon-carbon stretching fundamental was assigned at 1920.7 cm (-1). This paper presents results from new experiments that have enhanced the production of the molecule via laser ablation of a single sintered germanium-carbon rod, thus enabling the identification of two additional infrared active vibrational fundamentals. Ge participates strongly in one of these, the nu 4(sigma u) mode, and the cor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
6
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 21 publications
3
6
0
Order By: Relevance
“…The higher frequencies 2016, 1519 belongs to the asymmetric and symmetric stretching of C-C-C configurations and other frequencies are obtained due to symmetric, asymmetric and bending mode of vibrations. The present calculated frequencies are also in good agreement with other workers [20,27,28]. Our predicted IR is also good agreement with others values [27,28].…”
Section: Cluster Configurationsupporting
confidence: 93%
See 3 more Smart Citations
“…The higher frequencies 2016, 1519 belongs to the asymmetric and symmetric stretching of C-C-C configurations and other frequencies are obtained due to symmetric, asymmetric and bending mode of vibrations. The present calculated frequencies are also in good agreement with other workers [20,27,28]. Our predicted IR is also good agreement with others values [27,28].…”
Section: Cluster Configurationsupporting
confidence: 93%
“…The present calculated frequencies are also in good agreement with other workers [20,27,28]. Our predicted IR is also good agreement with others values [27,28].…”
Section: Cluster Configurationsupporting
confidence: 93%
See 2 more Smart Citations
“…From a series of experiments testing different ratios, it was concluded that a mass ratio of Ge: C = 0.45: 1 was optimum, in contrast to Ge: C = 1.5: 1 for GeC 3 Ge. 21 The evaporation of germanium and carbon was carried out using two neodymium doped yttrium aluminum garnet lasers ͑Spectra Physics͒ operating at 1064 nm in the pulse mode. The evaporated species were condensed in solid Ar ͑Matheson, 99.9995% purity͒ on a gold surfaced mirror cooled to ϳ10 K by the closed-cycle refrigeration system ͑ARS, Displex͒.…”
Section: Methodsmentioning
confidence: 99%