2018
DOI: 10.1016/j.npbr.2018.08.001
|View full text |Cite
|
Sign up to set email alerts
|

FT-Raman study of protein misfolding and renaturation in brain hippocampus

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
11
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(13 citation statements)
references
References 35 publications
2
11
0
Order By: Relevance
“…The peptide secondary structure characteristics were also found: i) Amide I: C=O and C=C elongation and the α-helix secondary structure detected at 1,661.5 cm -1 (very strong); ii) Amide III: strain (CH 2 ), 1,299.5 cm -1 (shoulder); β sheet at 1,232 cm -1 (weak) and β and disordered sheet at 1,264 cm -1 (weak). Also, in 1,447 cm -1 (very strong), a bending mode of CH 2 and CH 3 was found (Balgoon et al, 2018). In this way, the FT-Raman technique helped to verify if there was any interference with the water in the FTIR analyzes, since the water does not interfere with the light scattering of the FT-Raman (E. Vicente et al, 2015).…”
Section: Resultsmentioning
confidence: 98%
“…The peptide secondary structure characteristics were also found: i) Amide I: C=O and C=C elongation and the α-helix secondary structure detected at 1,661.5 cm -1 (very strong); ii) Amide III: strain (CH 2 ), 1,299.5 cm -1 (shoulder); β sheet at 1,232 cm -1 (weak) and β and disordered sheet at 1,264 cm -1 (weak). Also, in 1,447 cm -1 (very strong), a bending mode of CH 2 and CH 3 was found (Balgoon et al, 2018). In this way, the FT-Raman technique helped to verify if there was any interference with the water in the FTIR analyzes, since the water does not interfere with the light scattering of the FT-Raman (E. Vicente et al, 2015).…”
Section: Resultsmentioning
confidence: 98%
“…All methods are reported in accordance with ARRIVE guidelines. Rats were allowed to acclimatize to the laboratory environment for one week before the experiment 3,5,13,22 . All rats received the same basic diet during the experimental period (65 days).…”
Section: Animals and Experimental Designmentioning
confidence: 99%
“…SFTIRM data were collected at the IR beamline of SESAME (Synchrotron light for Experimental Science and Applications in the Middle East) light source, Jordan. For the microspectroscopy beamline the beam is directed to a Nicolet Continuum IR microscope (Thermo Fisher Scienti c©, USA) equipped with a liquid-nitrogen-cooled mercury-cadmium-telluride (MCT) detector 3,5,13,22 . The Continuum microscope is coupled to 8700 Thermo Spectrometer and the data collection was carried out using Thermo OMNIC software.…”
Section: Synchrotron-ftirm Measurementsmentioning
confidence: 99%
See 2 more Smart Citations