Abstract: In their recent work [1], authors have introduced and validated a new ductile design concept of confined concrete-filled polyvinyl-chloride tubular (CCFPT) columns through experimental and analytical studies. Confinement was provided with the use of a polyvinylchloride (PVC) tube and fiber-reinforced polymer (FRP) wrappings or FRP with a sandwiched layer of foam to enhance impact energy reduction due to potential FRP rupture and PVC fracture. In the present paper, additional flexural tests on CCFPT columns wer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
23
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 56 publications
(36 citation statements)
references
References 37 publications
0
23
0
Order By: Relevance
“…Energy absorption is the toughness of the material, as measured from the stress-strain data. It is the area under a stress-strain curve and is measured using the expression that is given in Equation (9). On literature, energy absorption was reported in different ways depending on the strain value that was chosen to end the integration [15,40,[42][43][44].…”
Section: Energy Absorption Capacitymentioning
confidence: 99%
See 3 more Smart Citations
“…Energy absorption is the toughness of the material, as measured from the stress-strain data. It is the area under a stress-strain curve and is measured using the expression that is given in Equation (9). On literature, energy absorption was reported in different ways depending on the strain value that was chosen to end the integration [15,40,[42][43][44].…”
Section: Energy Absorption Capacitymentioning
confidence: 99%
“…Work is a total force required to shorten the uPVC confined cylinder under axial compression and it is stored as energy in the material. Energy stored in the material is the area under the stress-strain curve, as expressed in Equation (9) and Figure 20. The work index is calculated to show how the material undergoes straining for the applied load beyond the elastic state.…”
Section: Work Indexmentioning
confidence: 99%
See 2 more Smart Citations
“…Fakharifar [17] analysed the effect of the type and thickness of FRP tube, compressible foam, and the loading zone, on the behaviour of PFCC. The experiment for the seismic resistance of PFCC was performed by Fakharifar [18], and high ultimate strength and good ductility of PFCC were demonstrated. Jiang [19] studied the influence of the axial force ratio, the layer and type of FRP on the circular section reinforced concrete composite column with FRP-PVC tube under cyclic loading.…”
Section: Introductionmentioning