Frontiers in elemental analysis by mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

1992
1992
2015
2015

Publication Types

Select...
6
2
2

Relationship

0
10

Authors

Journals

citations
Cited by 33 publications
(7 citation statements)
references
References 43 publications
0
7
0
Order By: Relevance
“…To these losses, incomplete extraction of the ions from the interface and their incomplete transmission inside the ion channel should be added, especially for light ions 27,39 and for ion beams analysed using quadrupole instruments 40 (especially of older designs 41 ) and (sector eld) instruments operated at a high resolution. 40,42 With older quadrupole ICPMS, only one ion is registered by the detection system for every 10 4 to 10 6 ions through the skimmer; 43,44 the quest for a more efficient extraction and transmission is still underway. 39 Finally, irrespective of the dead time related losses, the secondary electron multiplier is usually not 100% efficient in registering the arriving ions, as illustrated by the routine practice to optimise itat the expense of its life timeby increasing inter-dynode voltages.…”
Section: A Binomial Derivation Of the Poisson Process In Icpmsmentioning
confidence: 99%
“…To these losses, incomplete extraction of the ions from the interface and their incomplete transmission inside the ion channel should be added, especially for light ions 27,39 and for ion beams analysed using quadrupole instruments 40 (especially of older designs 41 ) and (sector eld) instruments operated at a high resolution. 40,42 With older quadrupole ICPMS, only one ion is registered by the detection system for every 10 4 to 10 6 ions through the skimmer; 43,44 the quest for a more efficient extraction and transmission is still underway. 39 Finally, irrespective of the dead time related losses, the secondary electron multiplier is usually not 100% efficient in registering the arriving ions, as illustrated by the routine practice to optimise itat the expense of its life timeby increasing inter-dynode voltages.…”
Section: A Binomial Derivation Of the Poisson Process In Icpmsmentioning
confidence: 99%
“…For the present work, a new version of the direct injection nebulizer (DIN) was used to coupled LC to ICP-MS (27,29,64). Figure 4 shows the schematic diagram of a DIN and a regular DIN torch.…”
Section: Direct Injection Nebulizationmentioning
confidence: 99%
“…It combines on-line separation, via surface modified silica capillaries for sample introduction, with an extremely sensitive element-specific detector (ICP-MS) following nebulization with a direct injection nebulizer (DIN), which is well-suited for liquid sample introduction into ICP instrumentation. Several papers describe the basic properties and analytical performance 13,14 of the direct injection nebulizer. The DIN is a microconcentric nebulizer placed inside the torch for liquid sample introduction into ICP instrumentation.…”
Section: Introductionmentioning
confidence: 99%