2020
DOI: 10.1016/j.aca.2020.08.017
|View full text |Cite
|
Sign up to set email alerts
|

From the bottom of an old jar: A fluorometric method for the determination of creatinine in human serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…Nowadays laboratories also routinely apply enzymatic assay kits with creatininase or creatinine deaminase 384−387 as well as GC-MS, LC-MS, and HPLC 388,389 for quantitative analysis of creatinine. 390,391 In 2016, a fluorescence turn-on probe was disclosed by the Dhara group that is applicable for the selective detection and quantification of creatinine in 10 mM PBS and biofluids. 367 The authors exploited the metal-coordinating property of creatinine, which was found to displace "Pd" from the ethylene−diamine binding station that was installed to a naphthalimide core (Figure 78).…”
Section: Amines (Other Than Amino Acids)mentioning
confidence: 99%
See 1 more Smart Citation
“…Nowadays laboratories also routinely apply enzymatic assay kits with creatininase or creatinine deaminase 384−387 as well as GC-MS, LC-MS, and HPLC 388,389 for quantitative analysis of creatinine. 390,391 In 2016, a fluorescence turn-on probe was disclosed by the Dhara group that is applicable for the selective detection and quantification of creatinine in 10 mM PBS and biofluids. 367 The authors exploited the metal-coordinating property of creatinine, which was found to displace "Pd" from the ethylene−diamine binding station that was installed to a naphthalimide core (Figure 78).…”
Section: Amines (Other Than Amino Acids)mentioning
confidence: 99%
“…Alternative methods for creatinine determination in blood (and urine) are therefore still on demand. Nowadays laboratories also routinely apply enzymatic assay kits with creatininase or creatinine deaminase as well as GC-MS, LC-MS, and HPLC , for quantitative analysis of creatinine. , …”
Section: Amines (Other Than Amino Acids)mentioning
confidence: 99%
“…We measured creatinine values in an ex vivo perfused hemi-liver on a hemodialysis loop Section S5 (Supporting Information). In order to measure creatinine concentrations with high accuracy, we adapted the protocol by Lewinska et al [56] for continuous measurements and the spectrophotometric measurements were verified by LC-MS Figure 2i. We monitored the creatinine concentration in the blood-based perfusate of the aforementioned human hemi-liver over the first 24 h of normothermic perfusion Figure 3e.…”
Section: Real-time Patient Monitoringmentioning
confidence: 99%