2019 International Conference on Smart Applications, Communications and Networking (SmartNets) 2019
DOI: 10.1109/smartnets48225.2019.9069774
|View full text |Cite
|
Sign up to set email alerts
|

From IEEE 11073 SDC Device Specializations to Assistive Systems: Rule-based Data Analysis for Minimal Invasive Surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…The system idea is concretized by system goals (SG) depicted in Table 1 . The requirements for specifying these system goals were extracted from six published articles on prototypic CAS for surgery [ 1 , 7 , 13 , 21 , 23 , 26 ]. Integration of CAS in clinical routine is still pending [ 1 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The system idea is concretized by system goals (SG) depicted in Table 1 . The requirements for specifying these system goals were extracted from six published articles on prototypic CAS for surgery [ 1 , 7 , 13 , 21 , 23 , 26 ]. Integration of CAS in clinical routine is still pending [ 1 ].…”
Section: Methodsmentioning
confidence: 99%
“…Context awareness in the system architecture according to [ 21 ] is based on rules that follow a strict event–condition–action pattern and are evaluated by the CAS themselves. If a defined event occurs and the stored conditions are fulfilled, an action is automatically triggered.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For use cases like the activation of a wash flow, the OR integration system or the HF generator may use remote control functionalities of the pump to trigger the desired behaviour for a certain duration. Smart surgical pumps will additionally optimise their control algorithms by taking preoperative patient and procedure information into account or by consuming current vital signs of the patient [2].…”
Section: B Smart Connected Pumpsmentioning
confidence: 99%
“…These standards are more specific than the core series, yet independent of actual devices and clinical use cases. [2] Whereas the exchange architecture and protocol are specified in much detail, there remains freedom in applying the standard to modelling the network representation of realworld medical devices [3]. This is intended but only partly desired: If two functionally similar devices from different manufacturers differ greatly in their model structure, their data may still safely be interpreted by a communication partner.…”
Section: Introductionmentioning