1996
DOI: 10.1021/ac9601775
|View full text |Cite
|
Sign up to set email alerts
|

Fritless Packed Columns for Capillary Electrochromatography:  Separation of Uncharged Compounds on Hydrophobic Hydrogels

Abstract: A novel column is described that does not require frits to keep packing material within a capillary. A continuous bed is prepared in situ in aqueous solution by radical copolymerization of N-isopropylacrylamide and 2-acrylamido-2-methylpropanesulfonic acid (the resultant gel is denoted poly(AMPS-co-IPAAm). N,N'-Methylenebisacrylamide is used for cross-linking. On the application of an electrical field, electroosmotic flow (EOF) is developed in the bed along the capillary, where fluid propulsion would be otherw… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
63
1
1

Year Published

1998
1998
2002
2002

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 149 publications
(65 citation statements)
references
References 42 publications
(58 reference statements)
0
63
1
1
Order By: Relevance
“…Slightly crosslinked gels and liquid (non-crosslinked) gels were employed for the enantiomer separations of Dns-AAs, homatropine and atropine. Koide and Ueno 29,30 prepared charged gel columns according to the previously reported method [31][32][33] with some modifications. A mixture of either poly β-CD or caboxymethyl β-CD polymers (chiral selector), Tween 20, AAm, BIS and AMPS (for the preparation of negatively charged gels) or N-(2-acrylamidoethyl)triethylammonium iodide (for the preparation of positively charged gels) in a Tirs-boric acid buffer (pH 8.1) containing ammonium persulfate (APS) and N,N,N′,N′-tetramethylethylenediamine (TEMED) was introduced into a fused silica capillary and allowed to stand for >5 h. The resultant gels generated substantial EOF, the direction of which depended on the charged monomer added, and therefore could be used to separate neutral enantiomers.…”
Section: Homogeneous Gel Columnsmentioning
confidence: 99%
“…Slightly crosslinked gels and liquid (non-crosslinked) gels were employed for the enantiomer separations of Dns-AAs, homatropine and atropine. Koide and Ueno 29,30 prepared charged gel columns according to the previously reported method [31][32][33] with some modifications. A mixture of either poly β-CD or caboxymethyl β-CD polymers (chiral selector), Tween 20, AAm, BIS and AMPS (for the preparation of negatively charged gels) or N-(2-acrylamidoethyl)triethylammonium iodide (for the preparation of positively charged gels) in a Tirs-boric acid buffer (pH 8.1) containing ammonium persulfate (APS) and N,N,N′,N′-tetramethylethylenediamine (TEMED) was introduced into a fused silica capillary and allowed to stand for >5 h. The resultant gels generated substantial EOF, the direction of which depended on the charged monomer added, and therefore could be used to separate neutral enantiomers.…”
Section: Homogeneous Gel Columnsmentioning
confidence: 99%
“…Over the last 20 years CE has demonstrated to be a fast and versatile analytical technique that combines simplicity with high reproducibility [2]. Narrow-diameter polyimide-coated fused silica capillaries assures flexibility and allows efficient heat dissipation, thereby permits the use of high field strength resulting in separation efficiencies over [105][106] where Ld is the length of the capillary to the detector, & is the migration time, and V is the applied voltage. where eo is the dielectric constant, y is the viscosity of the buffer, and 5 is the zeta potential on the surface.…”
Section: Capillary Electrophoresismentioning
confidence: 99%
“…At present, capillaries packed with the typical stationary phase for HPLC are used in various CEC studies. 3,4 On the other hand, monolithic stationary phases, [5][6][7][8][9][10][11][12][13][14][15] which are ungranular polymeric separation media, are attracting increasing attention in the field of CEC due to their simple preparation methods, wide variety of functionalization and good stability.…”
mentioning
confidence: 99%