2005
DOI: 10.1111/j.1365-2249.2005.02837.x
|View full text |Cite
|
Sign up to set email alerts
|

Frequent false positive beta human chorionic gonadotropin tests in immunoglobulin A deficiency

Abstract: SummaryA patient with IgA deficiency had a series of positive serum pregnancy tests which led to medical and surgical procedures for suspected molar pregnancy. These tests were found to be falsely positive due to heterophile antibody. The

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
2

Year Published

2007
2007
2018
2018

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 28 publications
(12 citation statements)
references
References 50 publications
(47 reference statements)
0
10
0
2
Order By: Relevance
“…Finally, clinical biochemistry laboratories should be aware that IgA de¢ciency has been reported to interfere with the determination of beta human chorionic gonadotrophin (bHCG) in some assays. 88 …”
Section: Resultsmentioning
confidence: 99%
“…Finally, clinical biochemistry laboratories should be aware that IgA de¢ciency has been reported to interfere with the determination of beta human chorionic gonadotrophin (bHCG) in some assays. 88 …”
Section: Resultsmentioning
confidence: 99%
“…These are called heterophilic antibodies. Humans with recent exposure to mononucleosis can be prone to develop HAAAs and those with IgA deficiency syndrome often have false positive assay problems due to heterophilic antibodies [ 186 ]. Each human antibody is bivalent so if an HAAA or heterophilic antibody is present in a person's serum it can bind and link together the immobilized and tracer antibodies making a capture antibody-heterophilic antibody-tracer antibody complex or a capture antibody-HAAA-tracer antibody complex.…”
Section: Hcg Immunoassaysmentioning
confidence: 99%
“…Sera of patients with IgA deficiency often contain heterophilic antibodies, possibly related to increased mucosal antigen exposure of the systemic circulation. Up to 30% of IgA-deficient sera led to false-positive hCG results as measured in three different assays [29]. Despite the incorporation of nonspecific blocking antibodies (Scantibodies Laboratory, Inc.) in the DPC hCG assay, 7.4% of the sera of IgA-deficient women showed false-positive results, again illustrating the imperfect nature of this modified assay.…”
Section: Review Of the Literaturementioning
confidence: 99%