2014
DOI: 10.1109/jestpe.2014.2344176
|View full text |Cite
|
Sign up to set email alerts
|

Frequency Support Functions in Large PV Power Plants With Active Power Reserves

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
80
0
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 160 publications
(82 citation statements)
references
References 13 publications
0
80
0
2
Order By: Relevance
“…2, the grid current i * g can then be derived from (1), as it is given by Volt.-Var control Reactive power control in order to maintain the grid voltage level [39,40]. However, it should be noted that for small PV systems, the line is mainly resistive, and thus the reactive power control is of less effectiveness compared to the conventional Var compensation plant Freq.-Watt control Based on the droop characteristic between grid frequency and active power production, this control feature is to achieve a constant grid frequency by regulating the active power injected into the grid [28,29,41, 42] P constraints Active power constraints [31,33], for example, delta power production, CPG, power ramp control, and peak power limiting control. The CPG control has been witnessed as an effective mean to mitigate the overloading happening through sunny days Dynamic grid support…”
Section: Flexible Power Control Strategymentioning
confidence: 99%
See 1 more Smart Citation
“…2, the grid current i * g can then be derived from (1), as it is given by Volt.-Var control Reactive power control in order to maintain the grid voltage level [39,40]. However, it should be noted that for small PV systems, the line is mainly resistive, and thus the reactive power control is of less effectiveness compared to the conventional Var compensation plant Freq.-Watt control Based on the droop characteristic between grid frequency and active power production, this control feature is to achieve a constant grid frequency by regulating the active power injected into the grid [28,29,41, 42] P constraints Active power constraints [31,33], for example, delta power production, CPG, power ramp control, and peak power limiting control. The CPG control has been witnessed as an effective mean to mitigate the overloading happening through sunny days Dynamic grid support…”
Section: Flexible Power Control Strategymentioning
confidence: 99%
“…[18][19][20][21], power quality enhancement [22][23][24][25][26][27], frequency control through active power curtailment (Freq.-Watt function) [13,[28][29][30], active power control (e.g. the P constraints) [31][32][33][34], and reliability-oriented thermal management/control [33,[35][36][37].…”
Section: Introductionmentioning
confidence: 99%
“…This is necessary for the PV station in order to provide a given amount of reserves, either in terms of absolute power (kW/MW) or as a fraction of available maximum power (reserve ratio). References [3]- [7], [10], [12] implement techniques that follow external power commands, in addition to frequency response, employing different MPP estimation methods. In [12] and [7], irradiance and temperature measurements are utilized to extrapolate datasheet information to the actual conditions, whereas in [3]- [6], [10] a mathematical model is applied to voltage and current measurements acquired by the dc/dc converter sensors.…”
Section: Introductionmentioning
confidence: 99%
“…References [3]- [7], [10], [12] implement techniques that follow external power commands, in addition to frequency response, employing different MPP estimation methods. In [12] and [7], irradiance and temperature measurements are utilized to extrapolate datasheet information to the actual conditions, whereas in [3]- [6], [10] a mathematical model is applied to voltage and current measurements acquired by the dc/dc converter sensors. The former approach is simpler, but compromised by the inevitable deviations of actual PV modules characteristics from datasheet values, as well as by the translation formulae employed.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the spatiotemporal uncertainties associated with their production, variable renewable generators are currently restrained by operators in their provision of Ancillary Services (AS), for which maximum reliability is a firm pre-requisite. However studies have identified that wind and photovoltaics (PV) power plants show technical capabilities to provide AS [1], [2]. The Irish TSO has issued a specific regulation for frequency control from wind power plants [3].…”
Section: Introductionmentioning
confidence: 99%