2011
DOI: 10.1177/1358863x11405397
|View full text |Cite
|
Sign up to set email alerts
|

Frequency interference artifact

Abstract: A 40-year-old Caucasian male with prior history of hypertension, dyslipidemia, and coronary artery disease was admitted with severe right lower extremity swelling and tightness. An magnetic resonance venogram (MRV) confirmed acute deep venous thrombosis (DVT) of the right common femoral, common iliac and external iliac veins along with femoro-popliteal, tibial and peroneal vein DVT. Pharmacomechanical thrombectomy and thrombolysis (PMTT) was offered, given his young age and severe symptoms. An initial venogram… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2016
2016
2018
2018

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 2 publications
(2 reference statements)
0
2
0
1
Order By: Relevance
“…68 The interaction between the frequency from the ultrasound transducer and the pulsations of lower frequencies from the EKOS system ends up creating a sort of fan-shaped, "windshield wiper" artifact ( Figure 21). The EKOS system is a form of catheter-based thrombolytic delivery system used to treat pulmonary emboli.…”
Section: Ultrasound Interference Artifactmentioning
confidence: 99%
See 1 more Smart Citation
“…68 The interaction between the frequency from the ultrasound transducer and the pulsations of lower frequencies from the EKOS system ends up creating a sort of fan-shaped, "windshield wiper" artifact ( Figure 21). The EKOS system is a form of catheter-based thrombolytic delivery system used to treat pulmonary emboli.…”
Section: Ultrasound Interference Artifactmentioning
confidence: 99%
“…It uses acoustic microstreaming and ultrasonic agitation via ultrasound energy from a series of ultrasound transducer elements to alter thrombus structure and allow the thrombolytic therapy to be more effective. 68 The interaction between the frequency from the ultrasound transducer and the pulsations of lower frequencies from the EKOS system ends up creating a sort of fan-shaped, "windshield wiper" artifact ( Figure 21).…”
Section: Ultrasound Interference Artifactmentioning
confidence: 99%
“…Die Schallgeschwindigkeit in Silikon (1485 m/s) unterscheidet sich nur gering von Fettgewebe [21]. Artefakte durch unterschiedliche Transducerfrequenzen wurden beschrieben [22,23].…”
Section: Schallausbreitungunclassified