2014
DOI: 10.1001/jamaophthalmol.2013.5511
|View full text |Cite
|
Sign up to set email alerts
|

Frequency-Doubling Technology Perimetry for Detection of the Development of Visual Field Defects in Glaucoma Suspect Eyes

Abstract: IMPORTANCE While standard automated perimetry (SAP) remains the reference standard for evaluation of visual field (VF) defects in glaucoma, this study demonstrates that frequency-doubling technology (FDT) perimetry is effective in monitoring visual field progression and may detect the onset of visual field defects earlier than SAP.OBJECTIVES To compare detection of the development of VF defects, rate of change of VF loss, and risk factors for progression between SAP and matrix FDT perimetry in glaucoma suspect… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
15
0
2

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(18 citation statements)
references
References 28 publications
0
15
0
2
Order By: Relevance
“…In glaucoma suspects, Meira-Freitas et al (2014) reported that faster rates of increase of FDT pattern deviation were related to higher chance of progression in SAP, and Liu et al (2014b) reported that approximately the same number of suspects developed reproducible defects in FDT or in SAP. In glaucoma patients, Liu et al (2014a) identified more progressing patients with FDT than SAP; however, Redmond et al (2013) identified more progressing patients with SAP than FDT. While some studies suggest that FDT may be useful to evaluate progression of glaucoma functional damage, further research is required to better assess its additional value to SAP, before recommending frequent clinical use.…”
Section: Frequency-doubling Technology Perimetrymentioning
confidence: 91%
“…In glaucoma suspects, Meira-Freitas et al (2014) reported that faster rates of increase of FDT pattern deviation were related to higher chance of progression in SAP, and Liu et al (2014b) reported that approximately the same number of suspects developed reproducible defects in FDT or in SAP. In glaucoma patients, Liu et al (2014a) identified more progressing patients with FDT than SAP; however, Redmond et al (2013) identified more progressing patients with SAP than FDT. While some studies suggest that FDT may be useful to evaluate progression of glaucoma functional damage, further research is required to better assess its additional value to SAP, before recommending frequent clinical use.…”
Section: Frequency-doubling Technology Perimetrymentioning
confidence: 91%
“…They also found faster rates of FDT PSD change in glaucoma suspect and ocular hypertensive eyes compared to SAP. 33 These studies, however, compared the tests directly, without consideration for the differences in scales. Our results are consistent with those reported by Redmond et al, 31 who did not find evidence that FDT is more sensitive than SAP using permutation of PLR.…”
Section: Discussionmentioning
confidence: 99%
“…29 Although these properties may provide potential advantages for FDT in monitoring glaucomatous progression, the results from several recent longitudinal studies do not conclusively show an advantage for FDT compared to SAP. 16,3033 …”
Section: Introductionmentioning
confidence: 99%
“…Although controversial, there is increasing evidence of the utility of frequency doubling technology perimetry (FDT) for the early detection of glaucoma [22,23]. There are no established criteria or commercially available tools for the detection of FDT VF progression.…”
Section: Frequency Doubling Technology Perimetrymentioning
confidence: 99%