Frequency-domain hydrodynamic modelling of dense and sparse arrays of wave energy converters

Abstract: Take-down policy If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 20 publications
(35 reference statements)
0
5
0
Order By: Relevance
“…via an umbilical to the surface). For the purposes of this research, we account for the presence of the central pillar and incorporate its radiation effects on the floaters [27]. The PTO system coupled to each floater comprises a piston moving within a pipe that connects the internal reservoir to the external flexible bladder (Fig.…”
Section: The Ocean Grazer Wec (Og-wec)mentioning
confidence: 99%
“…via an umbilical to the surface). For the purposes of this research, we account for the presence of the central pillar and incorporate its radiation effects on the floaters [27]. The PTO system coupled to each floater comprises a piston moving within a pipe that connects the internal reservoir to the external flexible bladder (Fig.…”
Section: The Ocean Grazer Wec (Og-wec)mentioning
confidence: 99%
“…In this study, the hydrodynamic coefficients with the two-body interaction were obtained using the BEM-Processes 2021, 9, 1721 6 of 18 based frequency-domain hydrodynamic solver WAMIT. The equation of the motion of the floats, considering the hydrodynamic interaction, can be expressed in terms of complex amplitude as follows [25,36]:…”
Section: External Forces Acting On the Floating Bodymentioning
confidence: 99%
“…This subject for WECs is more challenging and uncertain due to the absorption, radiation, and diffraction of waves from multiple WEC bodies in the farm [3]. These wave-structure effects caused by the WEC operation in an array could influence the power absorbance [4] which emerges studies on layout optimization [5]- [7].…”
Section: Introductionmentioning
confidence: 99%
“…It should be no surprise that the diversity of WEC concepts shows various destructive or constructive effects of WECs in a farm [7], [9], [10]. Therefore, there is no specific layout scheme that the whole industry can settle for it.…”
Section: Introductionmentioning
confidence: 99%