Frequency Characteristics Measurement of Overhead High-Voltage Power-Line in Low Radio-Frequency Range

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(13 citation statements)
references
References 6 publications
0
13
0
Order By: Relevance
“…A typical case of 150 kV single-circuit overhead HV transmission line is depicted in Figure 1 This three-phase five-conductor (n 150 kV = 5) overhead HV distribution line configuration is considered in the present work consisting of ACSR GROSBEK 3 × 374.77 mm 2 + 2 × 322.26 mm 2 conductors [13,[49][50][51].…”
Section: The Physical Bpl Layermentioning
confidence: 99%
See 1 more Smart Citation
“…A typical case of 150 kV single-circuit overhead HV transmission line is depicted in Figure 1 This three-phase five-conductor (n 150 kV = 5) overhead HV distribution line configuration is considered in the present work consisting of ACSR GROSBEK 3 × 374.77 mm 2 + 2 × 322.26 mm 2 conductors [13,[49][50][51].…”
Section: The Physical Bpl Layermentioning
confidence: 99%
“…Overhead 400 kV double-circuit overhead HV transmission phase lines with radii r 400 kV [13,[49][50][51][52].…”
Section: The Physical Bpl Layermentioning
confidence: 99%
“…HV overhead power lines radiate energy at high frequencies and interfere with other systems operating at the same frequencies. In Europe, the frequency range devoted to HV PLC system is from 30 kHz to 500 kHz [12][13][14]. HV PLC systems are not permitted to operate in the broadband, but rather in the frequency range which is a multiple of 4 kHz bands to limit the interference.…”
Section: From Hv Plc Systems To Advanced Power-line Monitoring Applicmentioning
confidence: 99%
“…The distance is limited by the noise, generated by corona phenomena (discharges generated by rated high voltage) and interfering signals [12][13][14]. Even though corona noise intensity varies with power frequency voltage, it doesn't make huge impact on ultra-narrow band systems.…”
Section: From Hv Plc Systems To Advanced Power-line Monitoring Applicmentioning
confidence: 99%
“…Moreover, two parallel neutral conductors spaced by Δ 150 kV n hang at heights h 150 kV n -conductors 4 and 5-(for more details see [2]). This three-phase five-conductor (n 150 kV = 5) overhead HV distribution line configuration is considered in the present work consisting of ACSR GROSBEK 3 × 374.77 mm 2 + 2 × 322.26 mm 2 conductors [1,2,[14][15][16][51][52][53][54].…”
Section: Overhead Hv Transmission Power Networkmentioning
confidence: 99%