Free-Breathing 3 T Magnetic Resonance T2-Mapping of the Heart

Abstract: The new, well-characterized 3 T methodology enables robust and accurate cardiac T(2)-mapping at 3 T with high spatial resolution, while the addition of a reference phantom improves reproducibility. This technique may be well suited for longitudinal studies in patients with suspected or established heart disease.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

22
112
1

Year Published

2014
2014
2019
2019

Publication Types

Select...
8
1

Relationship

5
4

Authors

Journals

citations
Cited by 81 publications
(138 citation statements)
references
References 21 publications
22
112
1
Order By: Relevance
“…For T 2 , the mean myocardial value measured with MRF was 38ms (min 34ms, max 43ms), which is consistent with the mean value obtained with the T 2 -prepared bSSFP sequence of 38ms (min 32ms, max 43ms). These measurements lie within the range of previously reported native myocardial relaxation times at 3T of T 1 from 1080-1500ms (16,18,24,38) and T 2 from 38-50ms (24,39). The mean M 0 measured in myocardium was 0.28 but exhibited wide variability across subjects (min 0.12, max 0.39).…”
Section: Human Volunteer Imagingsupporting
confidence: 85%
“…For T 2 , the mean myocardial value measured with MRF was 38ms (min 34ms, max 43ms), which is consistent with the mean value obtained with the T 2 -prepared bSSFP sequence of 38ms (min 32ms, max 43ms). These measurements lie within the range of previously reported native myocardial relaxation times at 3T of T 1 from 1080-1500ms (16,18,24,38) and T 2 from 38-50ms (24,39). The mean M 0 measured in myocardium was 0.28 but exhibited wide variability across subjects (min 0.12, max 0.39).…”
Section: Human Volunteer Imagingsupporting
confidence: 85%
“…In this study, the T2 value correlated inversely with wall thickness as the region of interest defined by the investigator may have included left ventricular cavity or epicardial fat voxels, an effect with could produce false positive results in clinical practice [8]. The normal myocardial T2 measure was lower at 3 T (39 ± 5 ms) [14].…”
Section: T2 Mapping Sequence: Principlesmentioning
confidence: 72%
“…High-resolution navigator-gated radial 2D T 2 maps 12 were acquired in 3 short-axis slices as a reference (see Table 1 for magnetic resonance pulse sequence details). The self-navigated isotropic 3D radial whole-heart T 2 map 11 (voxel size 1.72 x 1.72 x 1.72 = 5.1 mm 3 ) was obtained during free breathing.…”
Section: Methodsmentioning
confidence: 99%
“…Furthermore, absence of ACR when using a technique that is able to detect 1R will impact on the guidance of immunosuppression. This pilot study therefore aimed to validate a novel 3-dimensional (3D) self-navigated cardiac T 2 -mapping technique with high spatial resolution (1.72 x 1.72 x 1.72 = 5.1 mm 3 ) at 3 T throughout the whole heart 11 by direct comparison with 2D T 2 -mapping at high resolution (1.25 × 1.25 × 5 = 7.8 mm 3 ) 12 and EMB-based ACR detection.…”
mentioning