2020
DOI: 10.1016/j.sab.2020.105873
|View full text |Cite
|
Sign up to set email alerts
|

Fraunhofer-type signal for underwater measurement of copper sample using collinear long-short double-pulse laser-induced breakdown spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
21
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 16 publications
(22 citation statements)
references
References 38 publications
1
21
0
Order By: Relevance
“…The output beams of these two channels are combined inside the laser head and output from the same external telescope. The detailed optical diagram of LS-2145LIBS laser is available in the experimental section of our previous paper [8]. In addition, in order to measure the pulse shape of the LS-2145LIBS laser, a Si photodiode sensor (Hamamatsu, S1336-18BQ) was placed near the light path.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The output beams of these two channels are combined inside the laser head and output from the same external telescope. The detailed optical diagram of LS-2145LIBS laser is available in the experimental section of our previous paper [8]. In addition, in order to measure the pulse shape of the LS-2145LIBS laser, a Si photodiode sensor (Hamamatsu, S1336-18BQ) was placed near the light path.…”
Section: Methodsmentioning
confidence: 99%
“…Cui et al have studied the Fraunhofer-type signal for underwater measurement of copper samples. Their results have suggested that the Fraunhofer-type signal can possibly be used for quantitative measurement of underwater LIBS [8]. Zhang et al have proposed a capillary mode LIBS method to detect the elemental concentrations in solution.…”
Section: Introductionmentioning
confidence: 99%
“…The absorption phenomenon that appears in the early plasma stage is known as Fraunhofer-type absorption. 34,36,37 Usually, the plasma is not uniform with the ''cold'' outer plasma region and ''hot'' plasma core. During the early plasma stage, the continuum radiation from the ''hot'' plasma core is absorbed by the ''cold'' outer shell.…”
Section: Intra-pulse Delay Time Effectmentioning
confidence: 99%
“…33 The superior detection ability for underwater measurement was verified by the measurement of the Al sample and copper sample under water. 30,34 The accuracy of the DP-LIBS technique for underwater analysis has also been demonstrated, such as the calibration curve of copper alloy samples. 24 In these studies, the measured targets underwater were mainly Al alloy, copper alloy for qualitative and quantitative analysis of the DP-LIBS technique.…”
Section: Introductionmentioning
confidence: 98%
See 1 more Smart Citation