2002
DOI: 10.1140/epjd/e20020070
|View full text |Cite
|
Sign up to set email alerts
|

Fragmentation and reliable size distributions of large ammonia and water clusters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

5
134
0
5

Year Published

2010
2010
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 72 publications
(144 citation statements)
references
References 1 publication
5
134
0
5
Order By: Relevance
“…6,26,27 We obtained mean cluster sizes of N = 58 for the 40 eV data set, and N = 84 for both 60 eV data set (more details are available in the supplementary material 28 ). For the 40 eV data set, the nozzle temperature had to be estimated from the heating power, instead of a thermocouple reading.…”
Section: Methodsmentioning
confidence: 99%
“…6,26,27 We obtained mean cluster sizes of N = 58 for the 40 eV data set, and N = 84 for both 60 eV data set (more details are available in the supplementary material 28 ). For the 40 eV data set, the nozzle temperature had to be estimated from the heating power, instead of a thermocouple reading.…”
Section: Methodsmentioning
confidence: 99%
“…3 ) several other methods have been developed, e.g., electron diffraction, [29][30][31][32] cluster beam scattering by a buffer gas, 33 pickup of sodium atoms and photoionization, 34 and helium atom diffraction on clusters. 35 Here we are concerned with two methods for the mean cluster size determination using the pickup process: (1) The first method consists in measuring the variations of the average beam velocity with the pickup pressure.…”
Section: Introductionmentioning
confidence: 99%
“…The clusters were generated in a molecular beam machine with a reflectron time-of-flight ͑RETOF͒ mass spectrometer being described elsewhere in detail. 18,19 A water cluster beam is skimmed and crosses an atmosphere of sodium vapor created in a pickup cell ͑cell temperature of 490 K͒. The sodium doped clusters are detected by photoionization, mass resolved in the RETOF, and the ions are recorded by a multichannel plate.…”
mentioning
confidence: 99%
“…This setup is particularly capable of generating molecular beams with high abundances of large clusters. 18,19 Expanding pure water at a stagnation pressure of 6.5 bar ͑reservoir temperature of 430 K and nozzle temperature of 440 K͒, a cluster size distribution with a median of ͗n͘ = 300 is generated. The upper panel of Fig.…”
mentioning
confidence: 99%