2000
DOI: 10.1109/16.848302
|View full text |Cite
|
Sign up to set email alerts
|

Fracture strength and fatigue of polysilicon determined by a novel thermal actuator [MEMS]

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
65
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 99 publications
(68 citation statements)
references
References 16 publications
3
65
0
Order By: Relevance
“…Stress-life fatigue data were also reported by Kapels, Aigner and Binder [40] on 4 µm thick polysilicon. These authors used Weibull statistics to determine a mean fracture strength of their tensile specimens of 2.9±0.5 GPa, with a Weibull modulus of 6.4 ± 1.…”
Section: Figurementioning
confidence: 69%
See 2 more Smart Citations
“…Stress-life fatigue data were also reported by Kapels, Aigner and Binder [40] on 4 µm thick polysilicon. These authors used Weibull statistics to determine a mean fracture strength of their tensile specimens of 2.9±0.5 GPa, with a Weibull modulus of 6.4 ± 1.…”
Section: Figurementioning
confidence: 69%
“…Based on a wide spectrum of studies (listed in Tables 1 and 2) involving a range of different testing methods (described in the Appendix), stress-lifetime data (Figures 1, 10) for thin-film silicon show relatively consistent trends, specifically that stress amplitudes as low as half the (single-cycle) fracture stress can cause delayed fatigue failure, typically after 10 11 cycles or more [11,24,31,33,48] . Such fatigue failure has been reported for various modes of cyclic loading, specifically for fully reversed cyclic loading (R = -1) [4,[11][12][13][14][15]18,19,24,[30][31][32][33][34][35][41][42][43]48,49,[52][53][54]59] and tensile loading with a positive mean stress (R ≥ 0) [13,[21][22][23][25][26][27][28][29][33][34][35]40,[55]…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The upper limit of 400 MPa is imposed for the reliability of the polysilicon suspension. The fracture strength of polysilicon is reported to be a few gigapascals [7]; however, this threshold may be lowered during postprocessing and also, stresses may locally be higher in reality than in simulation. From our experience, we consider 400 MPa to be an upper limit for safe operation.…”
Section: Modelingmentioning
confidence: 99%
“…Methods in this group have been developed either for silicon and polysilicon [1,2] or metals [3,4,5]. The other group is the on-chip fatigue test method [6,7,8,9]. In this method microspecimen is fabricated with a microactuator on a chip so this group of methods are free from human error involved in fixing and alignment of microspecimen to the actuator or the test device.…”
Section: Introductionmentioning
confidence: 99%