2013
DOI: 10.1109/tii.2012.2209665
|View full text |Cite
|
Sign up to set email alerts
|

FPGA-Based Fast Detection With Reduced Sensor Count for a Fault-Tolerant Three-Phase Converter

Abstract: Additional information: Use policyThe full-text may be used and/or reproduced, and given to third parties in any format or medium, without prior permission or charge, for personal research or study, educational, or not-for-prot purposes provided that:• a full bibliographic reference is made to the original source • a link is made to the metadata record in DRO • the full-text is not changed in any way The full-text must not be sold in any format or medium without the formal permission of the copyright holders.P… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
37
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 70 publications
(37 citation statements)
references
References 15 publications
0
37
0
Order By: Relevance
“…For open-circuit switch fault detection, the method of [16,17] is used throughout this study. In this method, fault in each leg is diagnosed by comparing the measured and estimated pole voltages.…”
Section: F Fault Detection Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…For open-circuit switch fault detection, the method of [16,17] is used throughout this study. In this method, fault in each leg is diagnosed by comparing the measured and estimated pole voltages.…”
Section: F Fault Detection Methodsmentioning
confidence: 99%
“…A sliding mode observer is used for fault detection in the multicell converter presented in [15]. A very fast FPGA-based fault detection using a "time and voltage criterion" is presented in [16,17]. It is capable of detecting the fault and its location in a few tens of microseconds.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Both methods have been investigated in the literature. The voltage based methods are fast, simple and efficient [7]- [10]. Detection times of less than 10 μs have been presented in the literature [7], [8].…”
Section: Introductionmentioning
confidence: 99%
“…The voltage based methods are fast, simple and efficient [7]- [10]. Detection times of less than 10 μs have been presented in the literature [7], [8]. However, the presented methods are not cost effective, since it is necessary to use extra sensors in the power converters.…”
Section: Introductionmentioning