2001
DOI: 10.1128/jcm.39.7.2518-2524.2001
|View full text |Cite
|
Sign up to set email alerts
|

Fourth-Generation Enzyme-Linked Immunosorbent Assay for the Simultaneous Detection of Human Immunodeficiency Virus Antigen and Antibody

Abstract: The VIDAS HIV DUO Ultra demonstrated 100% sensitivity and 99.5% specificity overall, with a 99.7% specificity in low-risk individuals. The analytical sensitivity, as assessed by seroconversion panels and p24 antigen in samples, was equivalent to the sensitivity of the reference assays used to characterize these panels. The VIDAS HIV DUO Ultra is accurate, offers potential advantages over conventional HIV testing for time and cost savings, has walk-away capability, and correctly identifies both early and establ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

3
54
0
8

Year Published

2007
2007
2017
2017

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 80 publications
(65 citation statements)
references
References 14 publications
3
54
0
8
Order By: Relevance
“…Al comparar dos metodologías de tamizaje de HIV (HIV Ag/Ab combo y anticuerpos contra HIV) no se encontraron diferencias significativas (p=0.776). El HIV Ag/Ac está diseñado para detectar antígeno p24 así como anticuerpos contra HIV-1, HIV-1 grupo O y HIV-2 (28) . Diversas evaluaciones entre estos métodos demuestran ventas y desventajas símiles, siendo importante su valoración concernientes a interferentes, rendimiento diagnóstico y costo-efectividad (29,30,31) .…”
Section: Discussionunclassified
“…Al comparar dos metodologías de tamizaje de HIV (HIV Ag/Ab combo y anticuerpos contra HIV) no se encontraron diferencias significativas (p=0.776). El HIV Ag/Ac está diseñado para detectar antígeno p24 así como anticuerpos contra HIV-1, HIV-1 grupo O y HIV-2 (28) . Diversas evaluaciones entre estos métodos demuestran ventas y desventajas símiles, siendo importante su valoración concernientes a interferentes, rendimiento diagnóstico y costo-efectividad (29,30,31) .…”
Section: Discussionunclassified
“…On the other hand, if it were negative, it confirmed negative results. At the NBTS, HIV Ag-Ab detection was tested for all specimens using commercially available Genscreen Monolisa™ HIV Ag-Ab ULTRA ELISA kits manufactured by BIORAD (3,bd Raymond Poincare, 92430 Marnes-la-CoquetteFrance), according to the manufacturer's instructions [35][36][37]. …”
Section: Interpretation Based On Serial Algorithm IImentioning
confidence: 99%
“…An HIV infection can potentially be detected with 4th generation HIV assays within the first 2weeks after exposure [10,13,14]. However, in addition to the first diagnostic window, a so-called second diagnostic window has been reported; this second diagnostic window may occur when 4 th generation HIV assays are used.…”
mentioning
confidence: 99%
“…This is because HIV core protein appears transiently in the blood and has been used as a marker of antigenemia prior to a detectable humoral immune response directed against HIV [9]. Most people develop detectable antibody within 3-4 weeks after infection using third generation assays [10]. However, antibody may not be present in quantities greater than the minimum concentration detectable by some assays in the early stages of infection.…”
mentioning
confidence: 99%
See 1 more Smart Citation