2010
DOI: 10.1080/00268971003649307
|View full text |Cite
|
Sign up to set email alerts
|

Fourier-transform spectroscopy of HD in the vacuum ultraviolet at λ = 87–112 nm

Abstract: Absorption spectroscopy in the vacuum ultraviolet (VUV) domain was performed on the hydrogen-deuteride molecule with a novel Fourier-Transform spectrometer based upon wavefront division interferometry. This unique instrument, which is a permanent endstation of the undulator-based beamline DESIRS on the synchrotron SOLEIL facility, opens the way to Fourier-Transform spectroscopy in the VUV range. The HD spectral lines in the Lyman and Werner bands were recorded in the 87-112 nm range from a quasi-static gas sam… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
40
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
8
1

Relationship

5
4

Authors

Journals

citations
Cited by 34 publications
(40 citation statements)
references
References 38 publications
0
40
0
Order By: Relevance
“…This absorption facility was also used in a previous investigation on the Lyman and Werner bands of the HD molecule. 30 In the present study, a third type of measurement is performed in addition to the gas cell setup with two different coolants. The FTS is used to record absorption spectra from a D 2 molecular gas jet for the first time.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This absorption facility was also used in a previous investigation on the Lyman and Werner bands of the HD molecule. 30 In the present study, a third type of measurement is performed in addition to the gas cell setup with two different coolants. The FTS is used to record absorption spectra from a D 2 molecular gas jet for the first time.…”
Section: Methodsmentioning
confidence: 99%
“…27,28,30 Due to small alignment offsets of the heliumneon laser and the VUV beam relative directions, that may vary from run to run, the absolute calibration also varies for different runs, and can be improved upon by anchoring the spectra to several accurately known D 2 lines in addition to a few Xe and Kr lines that occur in the spectra, finding their origin in the gas filter used for attenuating the harmonics at short wavelengths produced in the undulator. Some 39 lines belonging to the…”
Section: Frequency Calibrationmentioning
confidence: 99%
“…For a detailed description of the FT-spectrometer we refer to Refs. [17,18,26]. For the broad, predissociated transitions (v 4) the cell-configuration was used.…”
Section: Methodsmentioning
confidence: 99%
“…[49][50][51] and general properties of ultraviolet interferometry 48 are given in detail elsewhere and are only briefly described here. The spectrometer is based upon a wave-front-division interferometer and may be operated at XUV and VUV wavelengths.…”
Section: Experimental Procedures and Analysismentioning
confidence: 99%