2002
DOI: 10.1016/s0009-2614(02)01457-4
|View full text |Cite
|
Sign up to set email alerts
|

Fourier transform phase shift cavity ring down spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
30
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(31 citation statements)
references
References 20 publications
1
30
0
Order By: Relevance
“…The multiplex features of broadband methods allow several target species to be detected simultaneously. Broadband CRD methods have been known for several years [22][23][24][25][26][27][28][29][30] and have already been applied to atmospheric trace sensing [14,31]. A drawback of these pulsed broadband CRD setups is that they require tunable laser sources along with unconventional light detection electronics and data sampling.…”
Section: Introductionmentioning
confidence: 99%
“…The multiplex features of broadband methods allow several target species to be detected simultaneously. Broadband CRD methods have been known for several years [22][23][24][25][26][27][28][29][30] and have already been applied to atmospheric trace sensing [14,31]. A drawback of these pulsed broadband CRD setups is that they require tunable laser sources along with unconventional light detection electronics and data sampling.…”
Section: Introductionmentioning
confidence: 99%
“…Ball and Jones, 2003;Brown, 2003) or a Xe-Arc lamp (e.g. Hamers et al, 2002;Fiedler et al, 2003) or they used inexpensive and small diode lasers. If highly coherent (and hence narrow-band) laser sources are used, large intensity fluctuations can occur because the laser emission profile only overlaps with a few cavity modes.…”
Section: Methodsmentioning
confidence: 99%
“…In the broadband version by 8 Hamers et al [7] the intensity-modulated light of a high pressure cw xenon arc was directed 9 into the cavity after passing through a Fourier Transform (FT) spectrometer, and the light 10 transmitted through the cavity was detected by a photomultiplier tube. The ratio of the FT of 11 the in-phase and out-of-phase components of the intensity modulated light exiting the cavity…”
Section: Phase-shift Crd Spectroscopymentioning
confidence: 99%
“…ods that determine the characteristic photon storage time in the cavity (ring-down approach 31 [6] or phase shift measurements [7]), and methods that measure the light intensity transmitted 32 through the cavity [8]. This book chapter predominantly aims at the discussion of the latter 33 type of approach.…”
mentioning
confidence: 99%
See 1 more Smart Citation