Four‐dimensional, multiphase, steady‐state imaging with contrast enhancement (MUSIC) in the heart: A feasibility study in children

Abstract: The 4D MUSIC technique may represent a new paradigm in MR evaluation of cardiovascular anatomy and function in children with complex congenital heart disease.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
58
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 50 publications
(59 citation statements)
references
References 26 publications
1
58
0
Order By: Relevance
“…FE-MUSIC leverages reliable cardio-respiratory gating and ferumoxytol enhancement at 3.0 T to generate 4D images of the beating heart with true isotropic voxel dimensions of 0.6–0.9 mm [1]. This was accomplished by exploiting the high relaxivity and stable blood-pool concentration of ferumoxytol for steady state imaging, combined with regular airway pressure and ECG signals for optimal cardio-respiratory gating.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…FE-MUSIC leverages reliable cardio-respiratory gating and ferumoxytol enhancement at 3.0 T to generate 4D images of the beating heart with true isotropic voxel dimensions of 0.6–0.9 mm [1]. This was accomplished by exploiting the high relaxivity and stable blood-pool concentration of ferumoxytol for steady state imaging, combined with regular airway pressure and ECG signals for optimal cardio-respiratory gating.…”
Section: Discussionmentioning
confidence: 99%
“…Imaging parameters for breath-held FE-CMRA were: repetition time/echo time (TR/TE) 2.9/0.9 ms; flip angle 15-17°; in-plane resolution 0.9–1.2 mm; slice thickness 0.9–1.1 mm; GRAPPA acceleration 3×–4×; 75% partial Fourier acquisition in both phase encoding directions. FE-MUSIC was acquired during continuous ventilation using the airway pressure signal for respiratory gating [1]. No adjustments were made to the ventilatory frequency, amplitude or waveform to maximize gating efficiency and the default settings were employed.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The total time for the l1-ESPIRiT reconstruction was less than one hour on a server with two 10-core CPUs. Scans were performed after injection of 0.1 mL/kg ferumoxytol (Feraheme; AMAG Pharmaceuticals, Waltham, Massachusetts, USA) for blood pool enhancement (2325). General anesthesia was used in the majority of cases (n=17, 77.3%).…”
Section: Methodsmentioning
confidence: 99%
“…Han et al also aimed to improve the image quality and exam efficiency in pediatric patients without requiring breath-holding, by developing a cardiac and respiratorygated high-resolution 3-dimensional (3D) magnetic resonance angiography technique [4]. Electrocardiogram-gating was used to generate multiple 3D angiography data sets across the cardiac cycle with a temporal resolution of 65-95 ms, isotropic spatial resolution of 0.6-0.9 mm, and scan time of 3.5-8 min.…”
Section: Cmr Techniquesmentioning