2006
DOI: 10.1016/j.actbio.2005.11.002
|View full text |Cite
|
Sign up to set email alerts
|

Fouling and non-fouling surfaces produced by plasma polymerization of ethylene oxide monomer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

15
124
0
1

Year Published

2007
2007
2015
2015

Publication Types

Select...
6
3

Relationship

3
6

Authors

Journals

citations
Cited by 115 publications
(140 citation statements)
references
References 28 publications
15
124
0
1
Order By: Relevance
“…has reported a similar study of protein adsorption on diglyme plasma-polymerized surfaces. The level of BSA adsorption on the DGpp films deposited at 1, 5 and 15 W was measured using QCM-D, and using the Sauerbrey equation they reported BSA adsorption of approximately 20, 25 and 110 ng cm 22 , respectively, compared with approximately 600 ng cm 22 measured on the control SiO 2 -coated quartz crystal [28].…”
Section: Characterization Of the Films Using Atomic Force Microscopymentioning
confidence: 99%
“…has reported a similar study of protein adsorption on diglyme plasma-polymerized surfaces. The level of BSA adsorption on the DGpp films deposited at 1, 5 and 15 W was measured using QCM-D, and using the Sauerbrey equation they reported BSA adsorption of approximately 20, 25 and 110 ng cm 22 , respectively, compared with approximately 600 ng cm 22 measured on the control SiO 2 -coated quartz crystal [28].…”
Section: Characterization Of the Films Using Atomic Force Microscopymentioning
confidence: 99%
“…The non-adhesive platform consists of plasma-deposited poly(ethyleneoxide) (PEO-like) coating which has already demonstrated high stability in biological environment such as cell culture conditions. [10][11][12] The Au NPs nanostructures are made by two methods, namely by direct spotting or by owing NPs suspension on PEO-like coated surfaces. Surface distribution and coverage of Au NPs on PEOlike surface as a function of the NPs size and concentration were investigated by Scanning Electron Microscopy (SEM) and monitored in real-time using a Quartz Crystal Microbalance with Dissipation Monitoring technique (QCM-D).…”
Section: Introductionmentioning
confidence: 99%
“…Aromatic C-H stretching vibrations, identified at 3025 cm -1 and 3061 cm -1 , are specific to polystyrene films. Therefore, the groups are only visible in the ppES and polystyrene spectra [13,14].…”
Section: A Ftir Spectra Analysismentioning
confidence: 99%