2017 IEEE Applied Power Electronics Conference and Exposition (APEC) 2017
DOI: 10.1109/apec.2017.7931122
|View full text |Cite
|
Sign up to set email alerts
|

Forward dual-active-bridge solid state transformer for a SiC-based cascated multilevel converter cell in solar applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…For small load, they tackle the change in load demand without changing in frequency for load frequency control system with demand-side control through the smart meter [4][5][6][7][8]. But small DG with gasifier plant was found to be effective in automatic shaking mechanism reducing the tar [9], adaptive predictive control for adjustment of oxygen concentration in syngas [10], performance control are done when the gasifier is unstable, robust optimal control for shell gasifier in LFC power plants [11][12][13][14][15][16], and solar farm was found controls technique battery storage [17], energy management unit and integrated control of photovoltaic (PV) solar farm [18][19][20], and PV solar farms feed active power during day time and become inactive in the night time [21][22]. Both, LFC systems help to reduce the demand for transmission by overcoming local and tie-line stability when control design appropriate for interconnected power systems [23][24].…”
Section: Introductionmentioning
confidence: 99%
“…For small load, they tackle the change in load demand without changing in frequency for load frequency control system with demand-side control through the smart meter [4][5][6][7][8]. But small DG with gasifier plant was found to be effective in automatic shaking mechanism reducing the tar [9], adaptive predictive control for adjustment of oxygen concentration in syngas [10], performance control are done when the gasifier is unstable, robust optimal control for shell gasifier in LFC power plants [11][12][13][14][15][16], and solar farm was found controls technique battery storage [17], energy management unit and integrated control of photovoltaic (PV) solar farm [18][19][20], and PV solar farms feed active power during day time and become inactive in the night time [21][22]. Both, LFC systems help to reduce the demand for transmission by overcoming local and tie-line stability when control design appropriate for interconnected power systems [23][24].…”
Section: Introductionmentioning
confidence: 99%
“…This isolation is provided by the intermediate DC/DC stage. A Dual Active Bridge (DAB) DC/DC converter is commonly used for this role as proposed by many recent works [14]- [16]. However, in most of the works, the required isolation is not a major issue in the design mainly due to the application of interest.…”
Section: Introductionmentioning
confidence: 99%