2005
DOI: 10.1016/j.jconrel.2005.08.022
|View full text |Cite
|
Sign up to set email alerts
|

Formulation optimization of photocrosslinked polyacrylic acid modified with 2-hydroxyethyl methacrylate hydrogel as an adhesive for a dermatological patch

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
53
0
3

Year Published

2008
2008
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 51 publications
(57 citation statements)
references
References 25 publications
1
53
0
3
Order By: Relevance
“…The application as wound dressing and electrically conductive pads was also reported [50]. These types of hydrophilic PSAs consisting of swollen polymers require a chemical or photo cross-linking to increase their very low creep resistance [51,52]. Very few investigations deal with alternative strategies in order to avoid a final curing, which could determine a physical or chemical instability of the loaded drugs.…”
Section: Psas Used In Pharmaceutical Fieldmentioning
confidence: 99%
“…The application as wound dressing and electrically conductive pads was also reported [50]. These types of hydrophilic PSAs consisting of swollen polymers require a chemical or photo cross-linking to increase their very low creep resistance [51,52]. Very few investigations deal with alternative strategies in order to avoid a final curing, which could determine a physical or chemical instability of the loaded drugs.…”
Section: Psas Used In Pharmaceutical Fieldmentioning
confidence: 99%
“…Swelling and gel fraction studies: Swelling and gel fraction studies were carried out on the basis of a previously reported literature [42]. Briefly, 0.1 g GG and TCG was weighed and placed in small dishes, which were carefully inserted into the glass flasks.…”
Section: Experimental Designmentioning
confidence: 99%
“…Sonuçta PEG-DA makromer; EGDMA çapraz bağlayıcı; DMPA fotobaşlatıcı ve distile su varlığında hidrojel sentezi gerçekleştirilmiştir. Çapraz bağlayıcı oranı arttıkça elde edilen hidrojellerin daha sert ve mekanik olarak daha dirençli oldukları ve ağırlıkça makromer oranının artmasıyla çapraz bağlayıcı oranının hidrojelin mekanik direncine olan etkisinin daha fazla olduğu gözlenmiştir [17][18][19][20].…”
Section: Hidrojel Senteziunclassified
“…Şişme yüzdeleri P302 hidrojeli için %131; P312 hidrojeli için %173 ve P332 hidrojeli için %164'tür. Bu durum yüksek DMPA miktarı çok miktarda serbest radikal oluş-turduğu ve böylece polimerizasyon reaksiyonu daha hızlı bir şekilde yürüdüğü şeklinde yorumlanmıştır [18][19][20][21][22].…”
Section: Hidrojellerin Dinamik şIşme Davranışlarıunclassified
See 1 more Smart Citation