2013
DOI: 10.1049/iet-pel.2012.0019
|View full text |Cite
|
Sign up to set email alerts
|

Formulation of line‐to‐line voltage total harmonic distortion of two‐level inverter with low switching frequency

Abstract: THD is the most common criterion to determine the harmonic content of each waveform. Conventional methods, which are usually used, result in approximate answers due to their inability to take all harmonic orders into account. This paper focuses on the three-phase two-level inverter and proposes two methods, founded on the basic definition of THD, to calculate its line voltage THD, precisely. The first method considers stepped essence of line voltage and the second uses its Fourier coefficients. By proposed met… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 11 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…It can be found that the three‐phase waveforms are symmetric and quasi‐sinusoidal, and the amplitude of the fundamental component in the phase back‐EMF is 44 V. Fig. 4 b illustrates the fast‐Fourier‐transformation (FFT) results of the phase back‐EMF waveform, and the higher order harmonic components are relatively low with a THD value of 4.5%, which can be predicted by the following formula [29]THD=n=2normal∞Vn2V1where V n is the amplitude of n ‐order harmonic components, and V 1 is the amplitude of fundamental component.…”
Section: Frpm Machine‐based Drive Systemmentioning
confidence: 99%
“…It can be found that the three‐phase waveforms are symmetric and quasi‐sinusoidal, and the amplitude of the fundamental component in the phase back‐EMF is 44 V. Fig. 4 b illustrates the fast‐Fourier‐transformation (FFT) results of the phase back‐EMF waveform, and the higher order harmonic components are relatively low with a THD value of 4.5%, which can be predicted by the following formula [29]THD=n=2normal∞Vn2V1where V n is the amplitude of n ‐order harmonic components, and V 1 is the amplitude of fundamental component.…”
Section: Frpm Machine‐based Drive Systemmentioning
confidence: 99%
“…However, the output of these inverters contain more harmonics, hence the usage of expensive and bulky low pass passive filters are desired before feeding the power to the utility grid. Further, high voltage stress and high switching loss forbears the application of these inverters in high power application [8]. Consequently multilevel inverters (MLIs) are evolved as best substitute for medium and high power conversion systems.…”
Section: Introductionmentioning