2011
DOI: 10.4081/dts.2011.e16
|View full text |Cite
|
Sign up to set email alerts
|

Formulation and evaluation of colon targeted tablets containing simvastatin solid dispersion

Abstract: Solid dispersions (SDs) of simvastatin with mannitol, Ineutic®, Pluronic® F-68, PEG 4000 and PVP K-30 were prepared and evaluated to deliver simvastatin to the colon in a pre-solubilized form. The formula of choice was compressed into fast disintegrating tablets using drug compatible excipients and was coated with Eudragit® S100 as a pH-responsive polymer. We investigated the effects of several variables related to both SD preparation (carrier type, combined carriers and drug to carrier ratio) and tablet coati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
8
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…Both of these peaks were from C-O stretching of secondary alcohol according to Elbary et al. 30 Small peak shifts to lower wavelengths were observed on SVS-coated samples, yet, the occurrence of these shifts could be explained by the combination of two adjoining peaks in the SVS-coated samples. Nevertheless, in the high-frequency region above 3000 cm −1 , a peak corresponding to free alcohol O-H stretching at 3548 cm −1 on the pure SVS powder was shifted to 3448 cm −1 on the SVS-coated sample.…”
Section: Resultsmentioning
confidence: 81%
See 4 more Smart Citations
“…Both of these peaks were from C-O stretching of secondary alcohol according to Elbary et al. 30 Small peak shifts to lower wavelengths were observed on SVS-coated samples, yet, the occurrence of these shifts could be explained by the combination of two adjoining peaks in the SVS-coated samples. Nevertheless, in the high-frequency region above 3000 cm −1 , a peak corresponding to free alcohol O-H stretching at 3548 cm −1 on the pure SVS powder was shifted to 3448 cm −1 on the SVS-coated sample.…”
Section: Resultsmentioning
confidence: 81%
“…30,31 The spectrum of SVS-coated coins showed another peak at 1387 cm −1 , while two peaks at 1389 cm −1 and 1369 cm −1 were observed on pure SVS powder, both of which were due to C-H bending. 30,29 The peak at 1256 cm −1 on the coated samples was derived from a C-O-C lactone stretch and was resolved in two peaks at 2166 cm −1 and 1225 cm −1 on pure SVS powder. 30 The peak at 1162 cm −1 on pure SVS and 1159 cm −1 on SVS-coated samples was due to a C-O-C ester stretch.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations