2020
DOI: 10.1016/j.ajodo.2019.03.028
|View full text |Cite
|
Sign up to set email alerts
|

Force degradation of orthodontic latex elastics analyzed in vivo and in vitro

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(15 citation statements)
references
References 12 publications
1
6
0
Order By: Relevance
“…When the OLE is immersed in the liquid for a long time, the latex absorbs much water, and the force value greatly decreases. OLE stretching can also decrease the force strength due to the breakage of latex secondary bonds that increases over time and results in primary bond rupture manifested as strength loss [18]. This phenomenon is in agreement with the result that the force value of OLE at 24 hours is the smallest among those for the other groups.…”
Section: Resultssupporting
confidence: 89%
“…When the OLE is immersed in the liquid for a long time, the latex absorbs much water, and the force value greatly decreases. OLE stretching can also decrease the force strength due to the breakage of latex secondary bonds that increases over time and results in primary bond rupture manifested as strength loss [18]. This phenomenon is in agreement with the result that the force value of OLE at 24 hours is the smallest among those for the other groups.…”
Section: Resultssupporting
confidence: 89%
“…Analyzing the existing literature about inter-arch elastics, many studies focused on testing inter-arch distances >20 mm, to simulate real clinical conditions (5,9,16,18,19). In previous works, force-extension curves were provided with distances arbitrarily set at 5-or 10-mm intervals from 0 to 60 mm.…”
Section: Discussionmentioning
confidence: 99%
“…The weakness of elastics is represented by their rapid deterioration and loss of elasticity into the oral environment (4,5). A review of the existing literature in the field showed that most of the studies examined the applied force of interarch elastics, at standard distances, and in a static environment (6,7).…”
Section: Introductionmentioning
confidence: 99%
“…At 4 and 8 hours, the force losses were near 35% and 40%. 29 Yang et al 30 concluded in his study that the force degradation of latex elastic in vivo is much greater than that in both air and artificial saliva. In vivo, the force value of the orthodontic latex elastics decreased sharply in the first hour.…”
Section: Discussionmentioning
confidence: 96%