2016
DOI: 10.1364/ol.41.001130
|View full text |Cite
|
Sign up to set email alerts
|

Focusing light through scattering media by full-polarization digital optical phase conjugation

Abstract: Digital optical phase conjugation (DOPC) is an emerging technique for focusing light through or within scattering media such as biological tissue. Since DOPC systems are based on time reversal, they benefit from collecting as much information about the scattered light as possible. However, existing DOPC techniques record and subsequently phase-conjugate the scattered light in only a single polarization state, limited by the operating principle of spatial light modulators. Here, we develop the first full-polari… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
32
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1
1

Relationship

5
5

Authors

Journals

citations
Cited by 66 publications
(32 citation statements)
references
References 25 publications
0
32
0
Order By: Relevance
“…The experimental PBR is 5.1 × 10 3 , and the background intensity is calculated over an area of 1.2 × 1.2 mm. The theoretical PBR is calculated by N /(2 πM ), where N is the number of optical degrees of freedom, M is the number of speckle grains in the DOPC focus, and the factor of 2 is because that the opal diffuser nearly completely scrambles the polarization and our system phase conjugates only a single polarization of the sample light [52] (see Supplement 1). The speckle size on the FLC-SLM was 7.6 μm, computed from the full width at half-maximum (FWHM) of the autocovariance function of the speckle patterns measured by a camera with a pixel size of 3.45 μm.…”
Section: Resultsmentioning
confidence: 99%
“…The experimental PBR is 5.1 × 10 3 , and the background intensity is calculated over an area of 1.2 × 1.2 mm. The theoretical PBR is calculated by N /(2 πM ), where N is the number of optical degrees of freedom, M is the number of speckle grains in the DOPC focus, and the factor of 2 is because that the opal diffuser nearly completely scrambles the polarization and our system phase conjugates only a single polarization of the sample light [52] (see Supplement 1). The speckle size on the FLC-SLM was 7.6 μm, computed from the full width at half-maximum (FWHM) of the autocovariance function of the speckle patterns measured by a camera with a pixel size of 3.45 μm.…”
Section: Resultsmentioning
confidence: 99%
“…By using a vector transmission matrix in the derivation [51,52], it is straightforward to see that all the conclusions we obtained in this work are still valid, except that all the PBRs are reduced by half. Such a PBR reduction can be understood by considering the enhanced background due to the field along a polarization direction orthogonal to the incident polarization direction.…”
mentioning
confidence: 82%
“…The ultimate depth is where the light is depolarized due to scattering to the noise level [20,21]. To quantify the depolarizing effect based on pure optical measurements, we measured the speckle contrast after light passed through scattering media with different thicknesses.…”
Section: Discussionmentioning
confidence: 99%