2014
DOI: 10.1016/j.chroma.2014.01.025
|View full text |Cite
|
Sign up to set email alerts
|

Focused ultrasound solid–liquid extraction for the determination of perfluorinated compounds in fish, vegetables and amended soil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
37
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 69 publications
(40 citation statements)
references
References 36 publications
2
37
1
Order By: Relevance
“…Extraction was carried out under conditions optimized in a previous work [29]. 0.5 g of sample was placed together with 7 mL of an ACN: Milli-Q water (9:1, v/v) mixture in a 50 mL vessel and surrogate standards (MPFHxS, MPFOS, MPFBA, MPFHxA, MPFOA, MPFNA, MPFDA, MPFUnDA and MPFDoDA) were added (20 μL of a 0.5 ng μL À 1 solution).…”
Section: Sample Treatment and Focused Ultrasound Solid-liquid Extractionmentioning
confidence: 99%
See 1 more Smart Citation
“…Extraction was carried out under conditions optimized in a previous work [29]. 0.5 g of sample was placed together with 7 mL of an ACN: Milli-Q water (9:1, v/v) mixture in a 50 mL vessel and surrogate standards (MPFHxS, MPFOS, MPFBA, MPFHxA, MPFOA, MPFNA, MPFDA, MPFUnDA and MPFDoDA) were added (20 μL of a 0.5 ng μL À 1 solution).…”
Section: Sample Treatment and Focused Ultrasound Solid-liquid Extractionmentioning
confidence: 99%
“…Alkaline digestion [26], acid digestion [27], ion-pair extraction [28], solvent extraction [19], pressurized liquid extraction (PLE) [17], focused ultrasound solid-liquid extraction (FUSLE) [29,30] and matrix solid-phase dispersion (MSPD) [18] are the most commonly used extraction techniques for the PFAS analysis in solid matrices.…”
Section: Introductionmentioning
confidence: 99%
“…However, the analyte concentration must be at least of several hundreds of nanograms per milliliter. For environmental matrices where PFASs are found at trace levels (a few nanograms per liter or per gram), LC-MS/MS is the preferred technique owing to is high sensitivity in comparison with accurate mass techniques [14,17,18,21]. The problem of target screening is that a number of related compounds remain undetected in the sample just because they were not selected a priori as the analyte [24].…”
Section: Introductionmentioning
confidence: 98%
“…Triple-quadrupole tandem mass spectrometry (QqQ-MS/ MS) in multiple selected reaction monitoring (SRM) mode is predominant owing to its selectivity and sensitivity [14,19,20]. However, high resolution mass spectrometers, such as time-of-flight (TOF), Fourier transform ion cyclotron resonance (FT-ICR), or Orbitrap can also be used and have the ability to allow post-target and non-target screening [24,25].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation