1966
DOI: 10.1021/ac60233a025
|View full text |Cite
|
Sign up to set email alerts
|

Fluorometric Determination of Selenium in Biological Material with 2,3-Diaminonaphthalene.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
153
0
8

Year Published

1972
1972
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 631 publications
(168 citation statements)
references
References 16 publications
(18 reference statements)
3
153
0
8
Order By: Relevance
“…In addition, when used the isotonic phosphate buffer containing penicillamine instead of the plasma in the selenium export experiment, the selenium species exported was found in the chemical form of selenotrisulfide. 41 These results suggested a relay mechanism for the selenium transport from the N-CPD to the MSD in the AE1 protein.…”
Section: Discussionmentioning
confidence: 89%
See 1 more Smart Citation
“…In addition, when used the isotonic phosphate buffer containing penicillamine instead of the plasma in the selenium export experiment, the selenium species exported was found in the chemical form of selenotrisulfide. 41 These results suggested a relay mechanism for the selenium transport from the N-CPD to the MSD in the AE1 protein.…”
Section: Discussionmentioning
confidence: 89%
“…41 The selenium standard solution [1000 ppm as selenium (IV) dioxide in 0.5 M nitric acid] for the fluorometry was obtained from Kanto Chemical Co., Inc.…”
Section: Determination Of Membrane Protein and Selenium Concentrationsmentioning
confidence: 99%
“…Cord-blood THg was used for the data analysis and maternal-hair THg was for a comparable index of prenatal methylmercury exposure. Cord plasma selenium concentrations were determined fluorometrically after ashing the plasma samples with a mixture of nitrate and perchloric acid (Watkinson 1966). Accuracy was ensured using a certified reference material (Seronorm Trace Elements Serum L-1, Lot 0903106, Sero, Norway) for quality control.…”
Section: Exposure Biomakersmentioning
confidence: 99%
“…The value of hematocrit was obtained after centrifugation at 11,000 rpm for 5 min with a Hematocrit Centrifuge (Kubota Model KH-120, Tokyo). Selenium was analyzed by the method of Watkinson (1966). Mercury was measured by the method of Yamamoto et al (1980), which enables the mercury measurement under coexistence of selenium.…”
Section: Methodsmentioning
confidence: 99%