2012
DOI: 10.1016/j.marchem.2012.01.004
|View full text |Cite
|
Sign up to set email alerts
|

Fluorometric detection of total dissolved zinc in the southern Indian Ocean

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
19
1

Year Published

2013
2013
2016
2016

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 20 publications
(25 citation statements)
references
References 30 publications
5
19
1
Order By: Relevance
“…Dissolved Zn concentrations profiles resemble those of the major nutrients, with large deep to surface concentration ratios [217,218]. Concentrations of dissolved Zn are <0.1 nM in surface waters of the world's oceans [217][218][219], with approximately 98% of this pool chelated by strong organic ligands [220,221]. This reduces the bioavailable fraction of Zn, the free metal ion, to concentrations as low as 1 pM, values which have been shown to limit phytoplankton growth in culture experiments [222][223][224][225].…”
Section: Zincmentioning
confidence: 99%
See 2 more Smart Citations
“…Dissolved Zn concentrations profiles resemble those of the major nutrients, with large deep to surface concentration ratios [217,218]. Concentrations of dissolved Zn are <0.1 nM in surface waters of the world's oceans [217][218][219], with approximately 98% of this pool chelated by strong organic ligands [220,221]. This reduces the bioavailable fraction of Zn, the free metal ion, to concentrations as low as 1 pM, values which have been shown to limit phytoplankton growth in culture experiments [222][223][224][225].…”
Section: Zincmentioning
confidence: 99%
“…Zinc is a notoriously pervasive contaminant, as it is frequently used on marine vessels and equipment. Therefore accurate measurements can only be made using strict safeguards during sample collection and analysis [219,221].…”
Section: Zincmentioning
confidence: 99%
See 1 more Smart Citation
“…Although this FIA technique has been used successfully on several shipboard transects and process studies in the open ocean [8][9][10], this method relies on a poorly selective fluorescent reagent which suffers from significant interferences from Ca, Mg and Cd [7]. In addition, FIA manifolds have high reagent consumption rates, necessitate regular calibrations, frequent maintenance and thus require highly trained analysts for routine operation onboard research vessels.…”
Section: Graphical Abstractmentioning
confidence: 99%
“…In addition, filtered (0.45 µm), acidified seawater samples (pH=1.7) collected in 2009 in the upper 1,300m of the south Indian subtropical gyre (32.2°S, 111.45°E) during the US-CLIVAR CO 2 Repeat Hydrography I05 transect [8,22] were analyzed for Zn using the proposed method. Prior to analysis, 20 mL aliquots of the stored acidified seawater samples (pH=1.7) were pipetted into 30 mL PTFE bottles and then buffered offline to pH 6.0 by adding 1 mL of ammonium acetate sample buffer (pH 9.1).…”
Section: Seawater Standards and Reference Seawater Samples Preparationmentioning
confidence: 99%