The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
2000
DOI: 10.1016/s0003-2670(00)00995-8
|View full text |Cite
|
Sign up to set email alerts
|

Fluorimetric determination of isoniazid by oxidation with cerium(IV) in a multicommutated flow system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
28
0
2

Year Published

2003
2003
2018
2018

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 90 publications
(30 citation statements)
references
References 20 publications
0
28
0
2
Order By: Relevance
“…Hence, the development of rapid and accurate analytical methods is important for the determination of INZ in the pharmaceutical formulation and human serum. Several methods are available for the determination of INZ such as spectrophotometry [30], fluorimetry [31], chromatography [32], capillary electrophoresis [33], and the electro-analytical methods [34][35][36]. The electro-analytical techniques are more interesting due to their good sensitivity, accuracy, simplicity, and rapidity.…”
mentioning
confidence: 99%
“…Hence, the development of rapid and accurate analytical methods is important for the determination of INZ in the pharmaceutical formulation and human serum. Several methods are available for the determination of INZ such as spectrophotometry [30], fluorimetry [31], chromatography [32], capillary electrophoresis [33], and the electro-analytical methods [34][35][36]. The electro-analytical techniques are more interesting due to their good sensitivity, accuracy, simplicity, and rapidity.…”
mentioning
confidence: 99%
“…The importance of INZ has prompted the development of some methods for its determination including chemiluminescence [3], fluorimetry [4], spectrophotometry [5,6], capillary electrophoresis [7] as well as several chromatographic methods [8][9][10]. The electroanalytical methods described in literature for INZ determination in pharmaceutical formulations and human serum have demonstrated success [11][12][13][14][15][16][17][18].…”
Section: Introductionmentioning
confidence: 99%
“…Para a construção de curvas analíticas é usual, mesmo em sistemas FIA, o preparo de diversas soluções de referência. Os primeiros trabalhos que ressaltavam a construção de curvas analíticas em sistemas de fluxo exploravam a diluição do analito em linha pela formação de gradiente de concentração 3,4 , pela dispersão da solução de referência no percurso analítico; pela diluição da amostra e adição padrão empregando reamostragem [5][6][7][8] ; a comparação entre os sinais transientes da solução-referência e das amostras em intervalos de tempo de leitura equivalentes [9][10][11] ; a diluição controlada da solução do analito no fluxo carregador, empregando duas bombas peristálticas de rotação variável [12][13][14][15] ; variação do grau de dispersão pela mudança do comprimento da alça de amostragem 16 ; diluição controlada em "loop" fechado 17 ; e, pelo emprego da transformada de Fourrier em associação ao movimento peristáltico dos fluidos 18 . O objetivo deste trabalho é avaliar a possibilidade de aplicação de dois procedimentos para a construção de curvas analíticas, empregando uma única solução de referência em sistema envolvendo a concentração do analito, em fase sólida, e detecção in situ.…”
Section: Introductionunclassified