Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2021
DOI: 10.1007/s10904-021-01943-0
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescent Polyimide Films Produced with Diatomite and Mesoporous Silica as Promising High-Tech Material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 40 publications
0
2
0
Order By: Relevance
“…The CNDs show homogeneous size distributions (approximately 3.0 nm), and the clear lattice spacing indicates the good crystallinity of the CNDs, as shown in Figure a and b. Pure PVA and g-films with different CND concentrations were characterized by SEM, as shown in Figure c to f. Compared with pure PVA, particles with a size of about 800 nm can be observed in g-films (0.5 and 1 mg/mL), due to the self-assembly in the phosphorescence films forming process . The self-assembly CNDs within the film are isolated by PVA at low concentration, while the self-assembly CNDs were further aggregated when the concentration increased to 3 mg/mL.…”
Section: Results and Discussionmentioning
confidence: 94%
See 1 more Smart Citation
“…The CNDs show homogeneous size distributions (approximately 3.0 nm), and the clear lattice spacing indicates the good crystallinity of the CNDs, as shown in Figure a and b. Pure PVA and g-films with different CND concentrations were characterized by SEM, as shown in Figure c to f. Compared with pure PVA, particles with a size of about 800 nm can be observed in g-films (0.5 and 1 mg/mL), due to the self-assembly in the phosphorescence films forming process . The self-assembly CNDs within the film are isolated by PVA at low concentration, while the self-assembly CNDs were further aggregated when the concentration increased to 3 mg/mL.…”
Section: Results and Discussionmentioning
confidence: 94%
“…Pure PVA and g-films with different CND concentrations were characterized by SEM, as shown in Figure 3c to f. Compared with pure PVA, particles with a size of about 800 nm can be observed in g-films (0.5 and 1 mg/mL), due to the self-assembly in the phosphorescence films forming process. 52 The self-assembly CNDs within the film are isolated by PVA at low concentration, while the self-assembly CNDs were further aggregated when the concentration increased to 3 mg/mL. The phosphorescence performance of the film with a high concentration degraded to some extent, due to possible electron/energy transfer between adjacent CNDs.…”
Section: ■ Results and Discussionmentioning
confidence: 99%