2018
DOI: 10.1016/j.optmat.2018.08.003
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescent biosensor for the selective determination of dopamine by TGA-capped CdTe quantum dots in human plasma samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
8
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(9 citation statements)
references
References 46 publications
1
8
0
Order By: Relevance
“…The XRD results showed re ection planes at (111), (220) and, (311) for CdTe and CdTe-X. We obtained almost similar patterns for all samples indicating similar cubic crystal structures for CdTe, and CdTe-X [57]. The mean crystalline size of CdTe and CdTe-X were determined according to FWHM of diffraction peak based on the Scherer's equation 3nm, which is consistent with the results of the HRTEM.…”
Section: Resultssupporting
confidence: 83%
See 1 more Smart Citation
“…The XRD results showed re ection planes at (111), (220) and, (311) for CdTe and CdTe-X. We obtained almost similar patterns for all samples indicating similar cubic crystal structures for CdTe, and CdTe-X [57]. The mean crystalline size of CdTe and CdTe-X were determined according to FWHM of diffraction peak based on the Scherer's equation 3nm, which is consistent with the results of the HRTEM.…”
Section: Resultssupporting
confidence: 83%
“…3(A) shows the FTIR spectra of TGA, TGA-caped QDs, and CdTe-X in the range of 200-4000 cm −1 . The characteristic peaks of CdTe and CdTe-X bands at 2563 cm −1 can be attributed to the Vibration band of S-H that is observed in the free TGA molecules disappeared on the coordination of these molecules with colloidal CdTe and CdTe-X [57,58]. This is evidence of the formation of the S-Cd bond between TGA ligand molecule and QDs.…”
Section: Resultsmentioning
confidence: 86%
“…Excessive exposure to this ion can cause adverse physiological reactions (such as vomiting, diarrhea, headache, and nausea). Prolonged exposure can lead to kidney failure, liver poisoning, and damage to the human central nervous system. With the advancement of industrial technology, increasing amounts of Hg 2+ are being used, which inevitably pollute water sources and soil. Therefore, it is important to detect Hg 2+ present in the environment. At present, atomic absorption spectroscopy, atomic fluorescence spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS) techniques are used to detect Hg 2+ . Although these instruments are very accurate and sensitive, they are expensive and complex . These factors limit their widespread use.…”
Section: Introductionmentioning
confidence: 99%
“…At present, the QD sensors commonly used for cadmium measurement are based on Cd 2+ , especially cadmium telluride (CdTe) and cadmium selenide (CdSe) QDs, and are all single-core QDs [30][31][32]. Most of these reported QDs use the turn-off mode for Cd 2+ detection; only a few use the turn-on mode, which has a lower false positive rate than the turn-off mode and a limit of detection (LOD) in the range of 11-62 µg/L (0.097-0.552 µmol/L) [33][34][35].…”
Section: Introductionmentioning
confidence: 99%