2020
DOI: 10.2116/analsci.20p228
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescent and Colorimetric Dual-signal Enantiomers Recognition via Enzyme Catalysis: The Case of Glucose Enantiomers Using Nitrogen-doped Silicon Quantum Dots/Silver Probe Coupled with β-D-Glucose Oxidase

Abstract: Chiral enantiomers recognition is important but facing tough challenges in the direct quantitative determination for complex samples. In this work, via chosing nitrogen-doped silicon quantum dots (N-SiQD) as optical nanoprobe and constructing N-SiQD/silver (N-SiQD/Ag NPs) complex, β-D-GOx as model enzyme and glucose enantiomers as analytes, a fluorescent and colorimetric dualsignal chiral sensing strategy was proposed herein for chiral recognition based on specific enzymecatalyzed reaction. N-SiQD can exhibit … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 53 publications
0
2
0
Order By: Relevance
“…In Table S1, we summarize some reported assays for the chiral discrimination of glucose enantiomers (Table S1). Based on the chirality selectors used, these methods can be divided into two categories, including (1) enzyme-based detection using glucose oxidase (GOx) and (2) non-enzyme-based detection. The former category is the most used while the latter is much less used. The enzyme GOx is only responsive to d -Glu but not to l -Glu, thus realizing enantiomeric discrimination.…”
Section: Resultsmentioning
confidence: 99%
“…In Table S1, we summarize some reported assays for the chiral discrimination of glucose enantiomers (Table S1). Based on the chirality selectors used, these methods can be divided into two categories, including (1) enzyme-based detection using glucose oxidase (GOx) and (2) non-enzyme-based detection. The former category is the most used while the latter is much less used. The enzyme GOx is only responsive to d -Glu but not to l -Glu, thus realizing enantiomeric discrimination.…”
Section: Resultsmentioning
confidence: 99%
“…As an important zero-dimensional carbon-based nanometer material, carbon dots (CDs) have been studied since 2004 (ref. 1–4 ) and widely used in biological analysis, 5,6 sensing, 7–9 catalysis, 10,11 bioimaging 12 and photothermal therapy 13–15 and bio-medicine. 16 They have various properties, including stable fluorescence photoluminescence, 17,18 low toxicity, 19 excellent biocompatibility, 20 good water solubility 21,22 and low-cost synthesis.…”
Section: Introductionmentioning
confidence: 99%