1968
DOI: 10.1021/j100855a027
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescence yields of aromatic compounds

Abstract: Values of fluorescence yields for 18 compounds in solution at 23°are reported and they are compared with previous literature values. Modifications of the technique of Weber and Teale for measurement of fluorescence yields are described. Fluorescein in 0.1 N NaOH and anthracene in ethanol are the best fluorescence standards on the basis of agreement of fluorescence yields with other work. The use of quinine as a fluorescence standard is complicated by variation of its fluorescence yield with H2SO4 concentration… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

15
361
0
3

Year Published

1977
1977
2002
2002

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 601 publications
(379 citation statements)
references
References 2 publications
15
361
0
3
Order By: Relevance
“…The yield of quininesulfate in 0.1 N H2SO4 was also measured, to check the sensitivity and exactness of the evaluation method. The obtained value of 0.52 is in good accordance with the value discussed in literature [4,17], Each value of rjF in Table 2 was repeatedly reproduced within an accuracy of 1 to 3% according to the excitation wavelength. New dye solutions were prepared for each set of experiments.…”
Section: Evaluation Proceduressupporting
confidence: 89%
“…The yield of quininesulfate in 0.1 N H2SO4 was also measured, to check the sensitivity and exactness of the evaluation method. The obtained value of 0.52 is in good accordance with the value discussed in literature [4,17], Each value of rjF in Table 2 was repeatedly reproduced within an accuracy of 1 to 3% according to the excitation wavelength. New dye solutions were prepared for each set of experiments.…”
Section: Evaluation Proceduressupporting
confidence: 89%
“…The fluorescence and excitation spectra were recorded with a Perkin-Elmer model MPF 44A fluorescence spectrophotometer provided with corrected spectra unit and the absorption spectra with a Shimadzu UV-VIS spectrophotometer model 2 10A. The fluorescence quantum yield of THQ in CH was measured from the corrected area under fluorescence curve relative to that of phenanthrene (26) in identical condition and the fluorescence life time T was determined therefrom (27).…”
Section: Methodsmentioning
confidence: 99%
“…( [1][2][3] Although the preparation of a supramolecular catalyst must incorporate a large degree of design, noncovalent forces are difficult to predict, and therefore the 'a priori' chances to prepare a catalyst with assembling properties are still very low, thus most of the supramolecular effects in catalysis are recognized 'post-factum'. Once the 'supramolecular catalyst' has been prepared, the challenge is to determine whether the catalytic activity of the catalyst is influenced by non-covalent assembling properties, for which well-chosen control experiments are required to determine both, the nature of the non-covalent interaction and their direct involvement in the rate and selectivity-determining steps of the catalytic reaction.…”
Section: Referencesmentioning
confidence: 99%
“…1 Free NHC ligands are often more sensitive to air and moisture than their corresponding metal complexes, which have proved to be remarkably resistant to oxidation. The first NHC complexes were described by Öfele and Wanzlick in 1968; 2,3 and Herrmann described the first catalytic application of NHC complexes in 1995.…”
Section: General Introductionmentioning
confidence: 99%
See 1 more Smart Citation