2003
DOI: 10.1016/j.chemphys.2003.08.013
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescence quenching of flavin adenine dinucleotide in aqueous solution by pH dependent isomerisation and photo-induced electron transfer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
93
0
1

Year Published

2005
2005
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 112 publications
(100 citation statements)
references
References 46 publications
6
93
0
1
Order By: Relevance
“…FAD allows studying the effect of dimer stacking, as dodecin traps FAD from solution in a closed conformation, forming a tryptophan-isoalloxazine-adenine-tryptophan instead of tryptophan-isoalloxazine-isoalloxazine-tryptophan aromatic tetrade (6). Steady-state and transient spectroscopy of FAD in solution demonstrated a quenching of the excited state of the flavin by interactions with the adenine subunit in the closed conformation (17,(45)(46)(47). If for the quenching mechanism the second aromatic moiety is important, one should notice a difference in the transient data for the different bound cofactors riboflavin and FAD, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…FAD allows studying the effect of dimer stacking, as dodecin traps FAD from solution in a closed conformation, forming a tryptophan-isoalloxazine-adenine-tryptophan instead of tryptophan-isoalloxazine-isoalloxazine-tryptophan aromatic tetrade (6). Steady-state and transient spectroscopy of FAD in solution demonstrated a quenching of the excited state of the flavin by interactions with the adenine subunit in the closed conformation (17,(45)(46)(47). If for the quenching mechanism the second aromatic moiety is important, one should notice a difference in the transient data for the different bound cofactors riboflavin and FAD, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…This is the range of the fluorescence for flavins in aqueous solutions. 43 When gold colloids are present (at all the excitation wavelengths), the fluorescence band is relatively weak but so is the surface enhancement below 520 nm.…”
Section: Effect Of Fluorescencementioning
confidence: 99%
“…[1][2][3][4] Time-resolved fluorescence measurements fully confirmed this early model of closed FAD. [5][6][7][8][9] However, structural investigations have always been an object of dispute. Indeed, X-ray structural access to closed FAD is difficult due to the inherent flexibility and conformational dynamics of FAD.…”
Section: Introductionmentioning
confidence: 99%