1997
DOI: 10.1016/s0883-2927(96)00047-9
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescence micro-spectrometry of synthetic and natural hydrocarbon fluid inclusions: crude oil chemistry, density and application to petroleum migration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
98
0
3

Year Published

2010
2010
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 203 publications
(104 citation statements)
references
References 14 publications
3
98
0
3
Order By: Relevance
“…UV microfluorescence spectroscopy can be used to better determine the composition and API gravity of the fluids, and to discriminate between separate populations of petroleum fluid inclusions, as it provides a more detailed evaluation of the fluorescence characteristics of petroleum fluids at a range of wavelengths [11,12,[44][45][46]. The fluorescence spectra for inclusion oils were measured with a CRAIC QDI 202Tm Microspectrophotometer (San Dimas, CA, USA), according to the methodology outlined by [46].…”
Section: Sampling and Methodologymentioning
confidence: 99%
See 3 more Smart Citations
“…UV microfluorescence spectroscopy can be used to better determine the composition and API gravity of the fluids, and to discriminate between separate populations of petroleum fluid inclusions, as it provides a more detailed evaluation of the fluorescence characteristics of petroleum fluids at a range of wavelengths [11,12,[44][45][46]. The fluorescence spectra for inclusion oils were measured with a CRAIC QDI 202Tm Microspectrophotometer (San Dimas, CA, USA), according to the methodology outlined by [46].…”
Section: Sampling and Methodologymentioning
confidence: 99%
“…The fluorescence spectra for inclusion oils were measured with a CRAIC QDI 202Tm Microspectrophotometer (San Dimas, CA, USA), according to the methodology outlined by [46]. In order to discriminate between different oil types, the maximum intensity of peaks (λ max ) and the relative intensity at 650 and 500 nm (Q R/G ; [44]) and at 500 and 430 nm (Q G/B ; [45]) were calculated for petroleum-bearing fluid inclusions.…”
Section: Sampling and Methodologymentioning
confidence: 99%
See 2 more Smart Citations
“…Stasiuk and Snowdon [24] measured the micro-fluorescence spectra of artificially synthesized hydrocarbon inclusions and natural hydrocarbon inclusions. The migration of oil and gas was revealed.…”
Section: Introductionmentioning
confidence: 99%