2002
DOI: 10.1089/108705702760047745
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescence Data Analysis on Gel-Based Biochips

Abstract: A series of biochip readers developed for gel-based biochips includes three imaging models and a novel nonimaging biochip scanner. The imaging readers, ranging from a research-grade versatile reader to a simple portable one, use wide-field objectives and 12-bit digital large-coupled device cameras for parallel addressing of multiple array elements. This feature is valuable for monitoring the kinetics of sample interaction with immobilized probes. Depending on the model and the label used, the sensitivity of th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2002
2002
2017
2017

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 10 publications
(17 citation statements)
references
References 0 publications
0
17
0
Order By: Relevance
“…Fluorescence was measured on a biochip portable fl uorescence analyzer with laser excitation (Institute of Molecular Biology) using 650/750-nm fi lters (excitation/recording) [2]. Fluorescence signals from each well of the biochip and concentrations o f all tumor mar kers were studied by means of ImagelAssay software (Institute of Molecular Biology).…”
Section: Methodsmentioning
confidence: 99%
“…Fluorescence was measured on a biochip portable fl uorescence analyzer with laser excitation (Institute of Molecular Biology) using 650/750-nm fi lters (excitation/recording) [2]. Fluorescence signals from each well of the biochip and concentrations o f all tumor mar kers were studied by means of ImagelAssay software (Institute of Molecular Biology).…”
Section: Methodsmentioning
confidence: 99%
“…A combination of up to four labels such as TCPP, FL, TR, and Cy5 can be used on the same chip. At the same time, TR and TCPP increase melting temperatures of perfect duplexes, probably because of their intercalating ability, and therefore, experiments with these labels must include carefully designed controls [Barsky et al, 2002].…”
Section: Commercial Development Of Gel-based Microchipsmentioning
confidence: 99%
“…A high-pressure mercury lamp is the source of epiillumination. The microscope works at up to four wavelengths simultaneously [Barsky et al, 2002]. We use routinely fluorescein, TR, and tetramethylrhodamine derivatives.…”
Section: Commercial Development Of Gel-based Microchipsmentioning
confidence: 99%
See 2 more Smart Citations