Fluidic Diode Autonomous ICD Selection Criteria, Design Methodology, and Performance Analysis for Multiple Completion Designs: Case Studies

Abstract: Inflow control device (ICD) technology helps in balancing the production across the entire interval, addressing some of the challenges associated with horizontal and deviated wells. Nevertheless, ICDs have limited capabilities in identifying and restricting unwanted fluids upon breakthrough. Autonomous ICD (AICD) technology functions similar to an ICD initially (i.e., balancing flux across the length of horizontal wells, effectively delaying breakthrough) but has the additional benefit of restricting the flow … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 9 publications
0
2
0
Order By: Relevance
“…As a very heterogeneous formation with fractures, vugs, and solution channels, regulating inflow is critical because fluids from these conduits can dominate wellbore flow and impede flow from other zones. AICD will control conduit flow and balance well inflow [19]. If these conduits are connected to a water source, water will skip oil through them.…”
Section: Resultsmentioning
confidence: 99%
“…As a very heterogeneous formation with fractures, vugs, and solution channels, regulating inflow is critical because fluids from these conduits can dominate wellbore flow and impede flow from other zones. AICD will control conduit flow and balance well inflow [19]. If these conduits are connected to a water source, water will skip oil through them.…”
Section: Resultsmentioning
confidence: 99%
“…Due to the formation's high heterogeneity caused by the presence of fractures, vugs, and solution channels, it is crucial to regulate inflow to prevent fluids from these conduits from dominating the flow into the wellbore and limiting flow from other zones. AICD will be able to control the flow from these pipes and maintain a steady flow of water into the well [56]. If these pipes are connected to a water supply, water will flow through them instead of oil, making a breakthrough nearly impossible to prevent.…”
Section: • a Highly Heterogeneous Formation With A High Length And Th...mentioning
confidence: 99%
“…Fripp et al 35 modeled the fluid diode AICD, introduced its working principle, and compared the simulated data with the measured data through computational fluid dynamics (CFD) simulation. Additionally, single-phase laboratory testing has been documented for fluid diode AICDs in papers SPE 160165, 36 SPE167379, 37 SPE170993, 38 SPE 166285, 39 and SPE180303, 40 three case histories have been documented for fluid diode AICDs in paper SPE 166495, 41 Shahreyar et al 42 and SPE 200255, 43 the use of fluid diode AICDs in both heavy and light oil fields were documented in the papers SPE 184094 44 and SPE 183863. 45 In addition to the abovementioned fluid diode AICD, there are many other types of channel-type AICD, such as a new adaptable inflow control devices designed by Zeng et al, 46 , 47 which guide flow through a Y-diverter and restricts water flow through a disk limiter.…”
Section: Structure and Working Principle Of The New Aicdmentioning
confidence: 99%