2003
DOI: 10.1007/s00604-003-0040-2
|View full text |Cite
|
Sign up to set email alerts
|

Flow-Through Bulk Optode for the Spectrophotometric Determination of Perchlorate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2006
2006
2019
2019

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Previously, García et al developed a new type of flow-ion sensitive bulk optode membrane that incorporates a chromogenic reagent (metallochromic indicator) in a plasticized poly (vinyl) chloride membrane entrapped in a cellulose support, which was applied to determining various contaminant metallic ions. The authors also described and tested the performance of a flow-optode membrane, which was constructed using a similar immobilization procedure, for the FI-spectrophotometric determination of perchlorate anion [4]. The optode incorporates the lipophilic pH indicator 5-octadecanoyloxy-2-(4-nitrophenylazo) phenol and methyltridodecylammonium as the active constituents.…”
Section: Absorbancementioning
confidence: 99%
“…Previously, García et al developed a new type of flow-ion sensitive bulk optode membrane that incorporates a chromogenic reagent (metallochromic indicator) in a plasticized poly (vinyl) chloride membrane entrapped in a cellulose support, which was applied to determining various contaminant metallic ions. The authors also described and tested the performance of a flow-optode membrane, which was constructed using a similar immobilization procedure, for the FI-spectrophotometric determination of perchlorate anion [4]. The optode incorporates the lipophilic pH indicator 5-octadecanoyloxy-2-(4-nitrophenylazo) phenol and methyltridodecylammonium as the active constituents.…”
Section: Absorbancementioning
confidence: 99%
“…They are noted for their high solubility, high solvation capacity and high reduction potential in water; properties which make perchlorate ions both chemically stable and a serious risk to human health. 1 During recent decades, different methods for determining perchlorate ions in water samples have been developed, including atomic absorption spectrometry, 2 spectrophotometry, 3,4 ion chromatography 5,6 and mass spectrometry. 7 However, electrochemical detection offers several advantages over these methods, such as ease of use, low cost, direct detection, miniaturisation and fast response times.…”
Section: Introductionmentioning
confidence: 99%
“…The coating solution and support type were those selected in a previous work [27], because they were found to provide better results for the determination of SCN - .…”
Section: Resultsmentioning
confidence: 99%
“…Diffuse reflectance spectra of the optode membrane were shown in the above work [27]. Curves corresponding to the protonated and deprotonated form of pH indicator were obtained by pumping 10 −2 M HClO 4 or 10 −2 M NaOH solution until a constant diffuse reflectance value was reached.…”
Section: Resultsmentioning
confidence: 99%