2018
DOI: 10.1016/j.cherd.2018.01.028
|View full text |Cite
|
Sign up to set email alerts
|

Flow studies in an in-line Silverson 150/250 high shear mixer using PIV

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
9
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 26 publications
1
9
0
Order By: Relevance
“…This could be due to the fact that for this particular hole size, the rotor doesn't entirely cover the top and bottom rows of holes. Similar results to this have been found byEspinoza et al (2018), who used particle image velocimetry (PIV) to study the flow field of an in-line Silverson mixer. They also concluded that the flow was non-uniform across the rows of holes in the stator screen.…”
supporting
confidence: 82%
“…This could be due to the fact that for this particular hole size, the rotor doesn't entirely cover the top and bottom rows of holes. Similar results to this have been found byEspinoza et al (2018), who used particle image velocimetry (PIV) to study the flow field of an in-line Silverson mixer. They also concluded that the flow was non-uniform across the rows of holes in the stator screen.…”
supporting
confidence: 82%
“…(Fig. 3, 4 and 5), scattering the laser required for effective PIV measurement [38]. As the distance from the tip was increased further, there was an increase in the observed velocity in all cases, with the exception of the glycerol and CMC solutions ( Fig.…”
Section: Comparative Assessment Of the Performance Of The Investigatementioning
confidence: 87%
“…PIV experimentation was conducted using a similar approach to that as detailed by Gabriele and co-authors [32] and Espinoza and co-authors [38], with some modifications required for the specific experimental setup in this study, and updates to the PIV setup, as detailed in Fig. 1 The delay between each frame in an image pair, ∆t d , was chosen in relation to the maximum displacement that a particle could travel in the defined interrogation window.…”
Section: Piv Experimentation and Processing Of Datamentioning
confidence: 99%
“…Note that the jet attaches to the leading edge of the stator and that the jet only fills a small portion of the slot [8,11,12]. This gives rise to a re-circulation region in the slots and, consequently, a "back-flow" of fluid that re-enters the slot from the bulk without passing the rotor [5,8,12,15,17,18].…”
Section: The Rotor-stator Mixermentioning
confidence: 99%