Abstract: We describe the analytical performance of a hybrid material composed of SiO 2 , Al 2 O 3 and TiO 2 . It was prepared by a sol-gel process and can act as an adsorbent in the continuous-flow enrichment of copper. A minicolumn was packed with the material, copper ions are adsorbed at pH 9.13, then eluted with 1.0 mol L −1 nitric acid, and determined by FAAS. The material was characterized by infrared spectroscopy, scanning electron and energy dispersive spectroscopy, energy dispersive X-ray fluorescence analysis,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
25
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 39 publications
(26 citation statements)
references
References 32 publications
1
25
0
Order By: Relevance
“…As seen from Table S1, methods such as ICP-MS (Wu and Boyle, 1997;Dai et al, 2012) and AAS (Chan and Huang, 2000;Lima et al, 2012) can detect Cu 2 þ ion with high sensitivity and selectivity, but they require large-scale instruments and highly trained operators restricting the practical on-site detection. The fluorometry methods also own good selectivity, but they are often troubled with complicated synthesis (Chan et al, 2010;Yu et al, 2011;Yuan et al, 2013;Zhang et al, 2013).…”
Section: Methods Performance Comparisonmentioning
confidence: 99%
See 1 more Smart Citation
“…As seen from Table S1, methods such as ICP-MS (Wu and Boyle, 1997;Dai et al, 2012) and AAS (Chan and Huang, 2000;Lima et al, 2012) can detect Cu 2 þ ion with high sensitivity and selectivity, but they require large-scale instruments and highly trained operators restricting the practical on-site detection. The fluorometry methods also own good selectivity, but they are often troubled with complicated synthesis (Chan et al, 2010;Yu et al, 2011;Yuan et al, 2013;Zhang et al, 2013).…”
Section: Methods Performance Comparisonmentioning
confidence: 99%
“…Methods such as ICP-MS (Wu and Boyle, 1997;Dai et al, 2012) and AAS (Chan and Huang, 2000;Lima et al, 2012) can detect Cu 2 þ ion with high sensitivity and selectivity but with requirements of large instruments. Compared with electrochemical techniques (Liu et al, 1999;Salaun and van den Berg, 2006;Lin et al, 2012) and fluorescence methods (Chan et al, 2010;Yu et al, 2011;Yuan et al, 2013;Zhang et al, 2013) are much simpler with detection by naked eyes and UV-vis spectroscopy (Lou et al, 2011;Liu et al, 2013;Shen et al, 2013;Wang et al, 2014).…”
Section: Introductionmentioning
confidence: 99%
“…39 The adsorption isotherm showed no hysteresis (Figure 4a) and its concave format indicates that the amount adsorbed approaches a limiting value. This limiting uptake is governed by the accessible pore volume rather than by the internal surface area.…”
Section: 40mentioning
confidence: 97%
“…One should note that, the presence of roughness on the surface of material can facilitate mass transfer and provides an increase in the surface area. 39,40 In order to obtain a rough estimation of mass percentages of the components and the dispersion of aluminium and tin in the surface of material, EDS spectrum (data not shown) and elemental mapping were recorded, respectively.…”
Section: Characterization Of Sio 2 /Al 2 O 3 /Sno 2 Ternary Oxidementioning
confidence: 99%
See 1 more Smart Citation