Flow injection ionization-tandem mass spectrometry-based estimation of a panel of lysophosphatidylcholines in dried blood spots for screening of X-linked adrenoleukodystrophy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 32 publications
0
7
0
Order By: Relevance
“…The PerkinElmer X-ALD NBS protocol employed a two-tiered testing process to detect X-ALD and eliminate interference occurring at the same mass as C26:0-lysophosphatidylcholine (C26:0-LPC) ( Figure 1 ). The first-tier test was performed via flow injection analysis tandem mass spectrometry (FIA-MS/MS) to measure C26:0-LPC [ 35 ]. An 1/8” punched dried blood spot was extracted in methanol at room temperature with a D4-C26:0-LPC internal standard.…”
Section: Methodsmentioning
confidence: 99%
“…The PerkinElmer X-ALD NBS protocol employed a two-tiered testing process to detect X-ALD and eliminate interference occurring at the same mass as C26:0-lysophosphatidylcholine (C26:0-LPC) ( Figure 1 ). The first-tier test was performed via flow injection analysis tandem mass spectrometry (FIA-MS/MS) to measure C26:0-LPC [ 35 ]. An 1/8” punched dried blood spot was extracted in methanol at room temperature with a D4-C26:0-LPC internal standard.…”
Section: Methodsmentioning
confidence: 99%
“…Yet, when using lysoPC C26:0 as only marker, there is a considerable overlap between controls and X-ALD patients. Similarly, to the method in this commercial kit, a study by Natarajan et al showed that utilizing flow injection mass spectrometry (FIA-MS), lysoPC C26:0 was overestimated especially in the lower concentration range [27]. Thus, maybe leading to impaired separation of controls and patients also in this commercial kit.…”
Section: Discussionmentioning
confidence: 88%
“… 15 A similar‐scaled study was conducted in India population aged 1–60 years and the four LPCs levels were 0.32, 0.17, 0.29, and 0.16 µM. 5 Tian et al conducted a new born screening study for determining C20:0‐C26:0‐LPCs levels in Shanghai population, involving 3078 DBS specimens. The median values of LPCs were 0.18, 0.14, 0.37, and 0.20 µM, respectively.…”
Section: Resultsmentioning
confidence: 99%
“… 4 For example, 26:0‐LPC is known to be elevated in patients and has been applied to screen X‐linked adrenoleukodystrophy (X‐ALD) and other peroxisomal disorders in the neonates. 5 Consequently, the analysis of LPCs as biomarkers of different disease states has gained considerable interest recently.…”
Section: Introductionmentioning
confidence: 99%