2000
DOI: 10.1039/b004032k
|View full text |Cite
|
Sign up to set email alerts
|

Flow injection analysis with inductively coupled plasma time-of-flight mass spectrometry for the simultaneous determination of elements forming hydrides and its application to urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
34
0
1

Year Published

2001
2001
2012
2012

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(35 citation statements)
references
References 16 publications
0
34
0
1
Order By: Relevance
“…Na ausência do efeito de matriz, a razão entre os coeficientes angulares deverá ser o mais próximo de 1, condição que assegura a determinação dos elementos com a calibração do instrumento com soluções aquosas. 18 Os dados das equações das retas, obtidas em meio de 10% v v -1 de HNO 3 e em meio das amostras estão apresentadas na Tabela 3. Os valores das razões entre os coeficientes angulares para Cd, Pb e As, nos diferentes meios, atestam que, nas condições otimizadas, as determinações foram feitas na ausência de interferên-cias da matriz.…”
Section: Características Analíticas Dos Métodosunclassified
“…Na ausência do efeito de matriz, a razão entre os coeficientes angulares deverá ser o mais próximo de 1, condição que assegura a determinação dos elementos com a calibração do instrumento com soluções aquosas. 18 Os dados das equações das retas, obtidas em meio de 10% v v -1 de HNO 3 e em meio das amostras estão apresentadas na Tabela 3. Os valores das razões entre os coeficientes angulares para Cd, Pb e As, nos diferentes meios, atestam que, nas condições otimizadas, as determinações foram feitas na ausência de interferên-cias da matriz.…”
Section: Características Analíticas Dos Métodosunclassified
“…136 The advantages of ICP-TOF-MS over sequential mass analyzers for fast transient detection and the simultaneous determination of a large number of isotopes in the flow injection (FI) peaks in trace metal analysis have been discussed. [137][138][139][140][141] The absence of spectral skew is highly appreciated. The applicability of a combined FI-hydride generation (HG)-ICP-TOF-MS system to the determination of As, Bi, Ge, Hg, Sb, Se and Sn in urine samples has been examined.…”
Section: Applications Of Icp-tof-ms Technique In Elemental Analysismentioning
confidence: 99%
“…The applicability of a combined FI-hydride generation (HG)-ICP-TOF-MS system to the determination of As, Bi, Ge, Hg, Sb, Se and Sn in urine samples has been examined. 138 No spectral skew was observed when monitoring 12 isotopes simultaneously in an FI peak of about 10 s width (50% height). Detection limits in the low pg ml -1 , linearity over more than five orders of magnitude, repeatability of 2 -5% and recoveries better than 80% were attained.…”
Section: Applications Of Icp-tof-ms Technique In Elemental Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Irrespective of such arguments, the use of TOF based detection is an attractive approach to overcome such difficulties and has been pursued in a number of publications. 13,14 Pela´ez et al 15 compared ICP-QMS and ICP-aa-TOF-MS for isotope ratio measurement precision on transients having different full width at half maximum (FWHM) characteristics. They recommended the TOF for peaks narrower than 8 s FWHM or when greater than 15 isotopes were to be measured.…”
Section: Introductionmentioning
confidence: 99%