1985
DOI: 10.1039/ap9852200015
|View full text |Cite
|
Sign up to set email alerts
|

Flow injection analysis with chemiluminescence detection: determination of hydrazine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
9
0

Year Published

1996
1996
2013
2013

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(10 citation statements)
references
References 0 publications
1
9
0
Order By: Relevance
“…The position of the confluence point is crucial for chemiluminescence detection in FIA or HPLC that involves fast lightproducing reactions and it is thought that ideally, the solutions should merge as close as possible to the point of detection. 4,19,20 We previously constructed a dual-inlet serpentine flow-cell ( Fig. 4a) that enabled solutions to be merged directly in front of the photodetector window.…”
Section: Confluence Point and Mixing Chambermentioning
confidence: 99%
See 1 more Smart Citation
“…The position of the confluence point is crucial for chemiluminescence detection in FIA or HPLC that involves fast lightproducing reactions and it is thought that ideally, the solutions should merge as close as possible to the point of detection. 4,19,20 We previously constructed a dual-inlet serpentine flow-cell ( Fig. 4a) that enabled solutions to be merged directly in front of the photodetector window.…”
Section: Confluence Point and Mixing Chambermentioning
confidence: 99%
“…6 To attain the greatest emission intensity within the flow-cell, the position of the confluence point is crucial, and for relatively fast chemiluminescence reactions it is generally thought that the solutions should merge at or as close as possible to the point of detection. 4,19,20 In our initial investigation of the GloCel detector, we examined two disks with serpentine channels. One contained a single inlet, in which case solutions were merged at an external Y-piece shortly before entering the flow-cell.…”
Section: Introductionmentioning
confidence: 99%
“…The pioneering work was with luminol and further examples were discovered among the linear acyl hydrazides . Hydrazine itself has been reported to be chemiluminescent on oxidation . Phenylhydrazine and a range of nitro‐substituted phenylhydrazines in propan‐2‐ol solutions have been found to be chemiluminescent on oxidation with acidified potassium permanganate and were applied for the determination of carbonyl compounds.…”
Section: Introductionmentioning
confidence: 99%
“…However, hydrazine derivatives and amines may interfere. A chemiluminescence method for the determination of hydrazine oxidized by hypochlorite under basic conditions has been presented (6). This method is also not specific for hydrazine.…”
Section: Introductionmentioning
confidence: 99%