2000
DOI: 10.1016/s0894-1777(00)00027-3
|View full text |Cite
|
Sign up to set email alerts
|

Flow field in a low-speed axial fan: a DPIV investigation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0
1

Year Published

2002
2002
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(11 citation statements)
references
References 6 publications
0
10
0
1
Order By: Relevance
“…Even at the most efficient angle of attack, significant boundary layer separations are observed on thick profiles-of relative thickness above 10%-while not on thin profiles [11] and the lift is reduced. The viscous dissipation is moreover greater for thick profiles, especially when they have rounded trailing edge as it is the case here [10]. Despite these drawbacks, the thick profiles have the advantage of having a more progressive stall than thin profiles, at higher angles of attack.…”
Section: Remarks and Discussion On The Modifications Of Overall Perfomentioning
confidence: 77%
See 1 more Smart Citation
“…Even at the most efficient angle of attack, significant boundary layer separations are observed on thick profiles-of relative thickness above 10%-while not on thin profiles [11] and the lift is reduced. The viscous dissipation is moreover greater for thick profiles, especially when they have rounded trailing edge as it is the case here [10]. Despite these drawbacks, the thick profiles have the advantage of having a more progressive stall than thin profiles, at higher angles of attack.…”
Section: Remarks and Discussion On The Modifications Of Overall Perfomentioning
confidence: 77%
“…Applied to low-speed axial-flow fans, one could a priori think that the extra thickness may increase the dissipation of energy in the von Kármán street behind the blades so that the performances of the fan decrease and the pressure fluctuations in its wake increase. The effects of blade thickness on the overall performances are not so well known [9][10][11][12] and to the best of our knowledge the influence on the dynamics remains an open question.…”
Section: Introductionmentioning
confidence: 99%
“…Estevadeordal등 [5] 은 DPIV를 사용하여 저속으로 회전 하는 축류팬의 유동특성을 연구하였다. Lee 등 [6] 은 전 향스윕된 축류팬에서 팁 볼텍스의 특성을 3차원 LDV 와 수치해석을 적용하여 유동특성을 연구하였다.…”
Section: 서 론unclassified
“…For examples, with a counting system detecting the rotor blade position, Ottavy et al reconstructed the velocity fields underthe various rotor-stator relative locationsfor high speed compressors [12]. Estevadeordal et al reproduced the flow fields at the certain rotor locations in a low speed axial fanwith a measurement system synchronized to the blade position [13].…”
Section: 1measurement Systemmentioning
confidence: 99%
“…Fixing the measurement systems in the stationary frame, numerous researchers established the ensemble averaged distribution of specific flow characteristics inside the rotating machinery by measuring synchronized to the rotation of rotor blades [12,13]. Compared with thetraditional rotor-stator combinationsin their studies where only two frames (one stationary and single rotating frame) exist, the contra-rotating rotors (requiredone stationary and two rotating framesto be considered) appear rather complicated to be tracked during experiment.…”
Section: Introductionmentioning